| Specification |
Installation Type: Threaded Type;
Sensing Type: Rectangular Temperature Sensors;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Integration;
Material: Ceramics;
Measuring Medium: Gas/Liquid;
IP Rating: IP65;
Customized: Customized;
Anti-Hazard Classification: Exd Iict6;
Characteristic: Suitable for High Pressure, High Temperature and W;
Wiring Method: Two-Wire System, Three-Wire System, Four-Wire Syst;
Measuring Range: -200~650degrees Celsius;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Ceramics;
Measuring Medium: Humidity;
IP Rating: IP65;
Customized: Customized;
DC power supply (default): DC 9-30V;
Accuracy: ±2%RH(60%RH,25℃);
Working temperature and humidity: -30℃~+80℃, 0%RH~95%RH (non-condensatio;
Probe operating temperature: -40℃~+120℃ Default: -40℃~+80;
Temperature display resolution: 0.1℃;
Humidity display resolution: 0.1%RH;
Long term stability: ≤1%RH/y,≤0.1℃/y;
Output signal: RS485 (Modbus protocol);
Installation method: wall-mounted;
Color: White;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Ceramics;
Measuring Medium: Humidity;
IP Rating: IP65;
Customized: Customized;
DC power supply (default): DC 9-30V;
Accuracy: ±2%RH(60%RH,25℃);
Working temperature and humidity: -30℃~+80℃, 0%RH~95%RH (non-condensatio;
Probe operating temperature: -40℃~+120℃ Default: -40℃~+80;
Temperature display resolution: 0.1℃;
Humidity display resolution: 0.1%RH;
Long term stability: ≤1%RH/y,≤0.1℃/y;
Output signal: RS485 (Modbus protocol);
Installation method: wall-mounted;
Color: White;
|
Installation Type: Contact;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Injection;
Material: Ceramics;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Product Name: Oxygen Probe;
Temperature Range: 1200-1750;
Measuring Range: 0.4-13ppm;
Measurement Accuracy: 0.1ppm;
Measured Rate: 98%;
Application: Measurement of Oxygen Content in Molten Steel;
|
Installation Type: Wall-Mounted Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog or Digital Output;
Production Process: Integration;
Material: Carbon Humidity;
Measuring Medium: Temperature and Humidity;
IP Rating: IP65;
Customized: Customized;
Product name: Wireless Temperature And Humidity Data Logger;
Range: 0-100%RH, -20-70℃;
Temperature measurement accuracy: 0-100%RH, -40-100℃;
Power supply: 5V;
Temperature accuracy: ±2%RH/±1.5%RH;
Operation method: Button;
Data export interface: USB/RS485;
Display method: Segment LCD;
Number of channels: 1-4 road;
Battery standby current: 500uA;
|