| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Color: Black;
Purpose: Household;
Materials: Plastic;
1: 1;
2: 2;
3: 3;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Single Package Size: 16X16X29cm;
Material: Aluminium, Copper, Plastic Steel;
Bcd Curve: C;
Rated Frequency: 50/60Hz;
Ue: 690V;
Accessories: of, SD, Mn, Mn;
Control: Manual;
Rated Current: 400A;
Packing: 4 PCS Per Carton;
Ui: 850V;
Single Gross Weight: 6.000kg;
Frequency: AC 50/60Hz;
Mounting Type: DIN Rail Mount;
Release Type: Electronic;
Uimp: 8kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Color: Grey and Dark Grey;
Product Name: Molded Case Circuit Breaker;
Single Package Size: 28.7X15.6X15.3 Cm;
Ue: 690V;
Accessories: of, SD, Mx, Mn;
Rated Current: 400A;
Control: Manual;
Ui: 800V;
Single Gross Weight: 6.000kg;
Uimp: 8kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Working Current: 1250A,1600A,2000A;
Product: Nw20n1;
Single Package Size: 57X52X62cm;
Standard: IEC60947-2;
Controltype: Push-Button;
Micrologic Control: Units Mic2.0A;
Rated Operational: Voltage AC50/60Hz.690V;
Rated Voltage: 690V;
Rated Frequency: 50/60Hz (Hz);
Mounting Mode: Drawout;
Rated Current: 2000A;
Range of Product: Nw;
Single Gross Weight: 100.000kg;
Application: Industrial,Protection;
Protection: Li, LSI, Lsig, Other;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product: Nt12h1;
Single Package Size: 42X37X42cm;
Standard: IEC60947-2;
Controltype: Push-Button;
Micrologic Control: Units Mic2.0A;
Rated Operational: Voltage 690V;
Rated Voltage: 690V;
Rated Frequency: Hz) AC50/60Hz;
Mounting Mode: Drawout;
Rated Current: 1250A;
Application: Industrial, Protection;
Protection: Li, LSI, Lsig, Other;
|