| Specification |
Type: Laser Dust Particle Counter;
Sample Feeding: Dry Dispersion;
Warranty: 1 Year;
Sampling Flow Rate: 2.83 L/Min (0.1 Cfm) ±5%;
Calibration Standards: Jjf1190-2008, GB/T6167-2007;
Maximum Sampling Concentration: 35,000 Particles/Liter;
Sampling Cycle Duration: Adjustable: 5 ~ 9999 Seconds;
|
Type: Static Laser;
Sample Feeding: Droplet;
Warranty: 2 Years;
Meansure Range: 0.1-270um;
Optical Path Calibration: Automatic;
Channels Number: 54;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Nasal Drug Products/Aerosol Research;
Reference Particle Size: D90/D50/D10;
Measurement Range Option: 0.1micron - 270 Microns;
Repeatably Error: <1% (Average Particle Size of National Standard S;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 1 Minutes;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 13kgs;
Volume: 612mm*230mm*325mm;
|
Type: Static Laser;
Sample Feeding: Droplet;
Warranty: 2 Years;
Meansure Range: 0.1-270um;
Optical Path Calibration: Automatic;
Channels Number: 54;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Nasal Drug Products/Aerosol Research;
Reference Particle Size: D90/D50/D10;
Measurement Range Option: 0.1micron - 270 Microns;
Repeatably Error: <1% (Average Particle Size of National Standard S;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 1 Minutes;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 13kgs;
Volume: 612mm*230mm*325mm;
|
Type: Static Laser;
Sample Feeding: Wet&Dry;
Warranty: 2 Years;
Meansure Range: 0.1-2000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 1 Micron - 2000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Weight: 58kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.1-800um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion,;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 0.1 Micron - 800 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 38kgs;
|