| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Specifications: Aperture 100 Aperture 120 Aperture 140;
Rated Current: 50A-800A;
Measure The Winding: 0.2s 0.2 0.5;
Relay Protection Winding: 10p10 10p15 10p20;
Operative Norm: IEC61869-1/2;
Ambient Temperature: -5^C--+40^C;
Rated Frequency: 50Hz 60Hz;
Insulation Voltage: 0.72/3kv;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 40.5/95/200kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Outndoor;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|