| Specification |
Application: Electronic, Instrument;
Type: Con Type & Csp Type;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Other;
Insulating Medium: Other;
Installation: Other;
Magnetic Circuit Structure: Other;
Voltage Transformation Principle: Electromagnetic Type;
Applicable Standard: ANSI C57.12.20;
Frequency: 60Hz /50Hz;
Core: C.R.G.O Core;
Winding: Cu-Cu; Cu-Ai ; Ai-Ai;
Product Scope: kVA: 15-75kVA;
Name: Three-Phase Oil-Immersed Distribution Transformers;
MOQ: ≥1;
Warranty: 1 Year/12 Months;
Hv: 12-13.2/23kv;
LV: 400V;
|
Application: Inflatable Switchgear, Rmu, Large Cable Monitoring;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single / Double Winding Optional;
Insulating Medium: Epoxy Resin;
Installation: Split-Core Hoop Mounting (No Cable Disconnection);
Magnetic Circuit Structure: Split-Type Toroidal Magnetic Core;
Voltage Transformation Principle: Electromagnetic Induction Principle;
Rated Secondary Current: 5A or 1A;
Accuracy Class: 0.2 / 0.5 / 1 / 10p5 / 10p10;
Product Width: 80 mm;
Rated Frequency: 50/60Hz;
|
Application: Instrument, Protection;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Voltage Measurement and Power System Protection;
Winding Form: Multi-Layer Layered Winding;
Insulating Medium: Epoxy Resin;
Installation: Base-Plate Bolt Mounting;
Magnetic Circuit Structure: Shell-Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy Class: 0.2 / 6p or 0.5 / 6p;
Rated Secondary Output: 20/50 Va or 30/50 Va;
Limit Output: 400 Va;
Rated Insulating Level: 24 / 65 / 125 Kv;
Overall Dimensions: 380mm*240mm*332mm;
Product Standard: GB 20840.3-2013;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input Current: 5-1000A;
Secondary Output Current: 5A, 1A, 100mA, 75mA, 40mA, 20mA, 10mA, 5mA, 1.25mA;
Rated Voltage: AC0.66kv=AC0.69kv;
Frequency: 50-60Hz;
Altitude: Less Than 3000m;
Inductor Diameter: 10, 16, 24, 36, 50mm;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input Current: 5-1000A;
Secondary Output Current: 5A, 1A, 100mA, 75mA, 40mA, 20mA, 10mA, 5mA, 1.25mA;
Rated Voltage: AC0.66kv=AC0.69kv;
Frequency: 50-60Hz;
Altitude: Less Than 3000m;
Inductor Diameter: 10, 16, 24, 36, 50mm;
|