| Specification |
Application: Electronic, Instrument;
Type: Con Type & Csp Type;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Other;
Insulating Medium: Other;
Installation: Other;
Magnetic Circuit Structure: Other;
Voltage Transformation Principle: Electromagnetic Type;
Applicable Standard: ANSI C57.12.20;
Frequency: 60Hz /50Hz;
Core: C.R.G.O Core;
Winding: Cu-Cu; Cu-Ai ; Ai-Ai;
Product Scope: kVA: 15-75kVA;
Name: Three-Phase Oil-Immersed Distribution Transformers;
MOQ: 1 Piece;
Warranty: 1 Year/12 Months;
Hv: 12-13.2/23kv;
LV: 400V;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Input: 0~100A AC;
|
Application: Electronic, Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Weight: 28kg;
Rated Frequency: 50Hz or 60Hz;
Insulation Level: 12/42/75kv,7.2/30/60kv;
Power Factor: Cosφ=0.8;
Ambient Temperature: -5ºC~+40ºC;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Input: 1A 5A 10A 20A ~ 50A 100A;
Rated Output: 1mA 2.5mA , 5mA , 10mA , 25mA 50mA;
Turns Ratio: 1:1000 1:2000;
Accuracy: 0.1 Class 0.2 Class;
Linearity: 0.1% 0.2%;
Compressive Strength: 3kv/50Hz/1min;
Operating Temperature: -40℃~+85℃;
Flame Retardant Properties: UL94-V0;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor/Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Weight: 5kg;
Rated Frequency: 25- 60Hz;
Insulation Level: 0.72/3/10kv;
Power Factor: Cosφ=0.8;
Ambient Temperature: -5ºC~+40ºC;
|