| Specification |
After-sales Service: Support Remote Online Service, Online Video Servic;
Type: Brinell Hardness Tester;
Measuring Range: Hbw;
Application: Metal, Plastic, Ceramics and Glass, Stone;
Standard: ISO, ASTM, GB/T, BSEN;
Warranty: 1 Year;
Mobility: Desktop;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 220V;
Support Language: English;
Customized: Customized;
Service Support: OEM ODM;
Language: Chinese and English;
MOQ: 1 PCS;
|
After-sales Service: Online;
Type: Vickers Hardness Tester;
Measuring Range: HV;
Application: Metal;
Standard: ISO, ASTM, GB/T;
Warranty: 1 Year;
Mobility: Desktop;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 220V;
Support Language: English;
Customized: Non-Customized;
Model: Xhtv-1000z;
Test Range: 1hv~2967hv;
Name: Vickers Hardness Tester;
Loading Method: Automatic;
Objective: 10X, 40X;
Dwell Time: 0~60s;
Light Source: Halogen Lamp;
Max Sample Height: 170mm;
Throat Depth: 130mm;
Power Supply: 220V;
Packing Size: 650*380*960mm;
Gross Weight: 62mm;
Payment Term: T/T;
Delivery Time: 15~20 Days;
MOQ: 1 Unit;
|
After-sales Service: Training+After Sales Support;
Type: Rockwell Hardness Tester;
Measuring Range: HRA;
Application: Metal;
Standard: ISO, ASTM;
Warranty: 1 Year;
Mobility: Desktop;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 220V;
Support Language: English;
Customized: Non-Customized;
LCD Screen Size: 118X99mm;
Rockwell Scale: Hra,Hrb,HRC,Hrd,Hre,Hrf,Hrg,Hrh, Hrk,Hrl, Hrm,Hrr,;
Conversion Scale: Hra, Hrb, HRC, Hrd, Hrf, Hv, HK, Hbw, H15n, H30n,;
Hardness Value Range: Hre:70~100 Hrl:50~115 Hrm:50~115 Hrr:50~115;
Loading Method: Automatic;
Data Output: Built-in Printer and RS-232 Port;
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Total Alkalinity;
Measuring Range: 0.53 - 2050ppm CaCO3;
Application: Demineralized Water Reverse Osmosis Boiler Water;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 220V;
Support Language: English;
Customized: Non-Customized;
Output: 4 - 20mA;
Measuring Principle: Titration Colorimetry;
Relay Output: 2 Passive Relay Output Nc / No, 250VAC 4A;
Optional Units: Mmol / L, Ppm CaCO3, ° Dh, ° F;
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Iron ions (divalent iron + trivalent iron);
Measuring Range: low range:0.01-0.5mg/L High range:0.2-6.0mg/L;
Application: boiler feedwater Drinking Water Iron removal Proce;
Standard: ISO;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Colourimetric method;
Rated Voltage: 85 - 265 VAC, 47-63Hz;
Support Language: English;
Customized: Non-Customized;
Measuring Principle: Titration Colorimetry;
|