| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Polycarbonate Plastic;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Weight: 1000g;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: Cosφ=0.8(Lag);
Ambient Temperature: -5ºC~+40ºC;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044; IEC 61869; ANSI/IEEE C57.13;
Rated Primary Current: 5-1000A;
Rated Load: ≤15va;
Rated Frequency: 50Hz or 60Hz;
Rated Secondary Current: 5A or 1A;
Rated Dynamic Current: 130ka;
Rated Insulation Level: 12/42/75kv;
Fs: ≤10;
Weight (Kg): 22;
Key Word: Transformador De Corriente;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv, 6kv;
Rated Load: ≤240va;
Cosø: 0.8 (Lag);
Key Words: International Potential Transformer;
Key Word: Instrument Potential Transformer;
Model: Potential Transformers and Current Transformers;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 35kv, 24kv, 17.5kv, 15kv, 10kv, 6kv;
Rated Load: 3000va;
Cosø: 0.8 (Lag);
Key Words: 15kv Potential Transformer Manufacturers;
Key Word: High Voltage Transformer Manufacturers;
Model: PT Transformer;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 33kv, 24kv, 10kv, 6kv;
Rated Load: ≤150va;
Cosø: 0.8 (Lag);
Key Words: Low Voltage Transformer;
Applications: Resin Cast Voltage Transformer 24kv;
Model: Voltage Measurement Transformer;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|