| Specification |
Application: Power, Electronic, Instrument;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Warranty: One Year;
Service Life: More Than 20 Years;
Efficiency: 99%-99.99%;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EE;
Brand: Kete;
Core Material: Silicon Steel Sheet;
Winding Material: Copper/Aluminum;
Taping Range: ±10%;
Voltage Regulator: 2 Steps;
Standard: IEC60076,GB1094;
Insulation Class: a;
Frequency: 50Hz/60Hz;
Coil Structure: Toroidal;
Connection: Yyn0 or Dyn11;
Outline Shape: Vertical Transformer;
Moisture-Proof Method: Sealed;
High Voltage: 35kv;
Low Voltage: 0.4kv;
Capacity: 630kVA 800kVA;
Voltage Regulation Method: Oltc;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EE;
Brand: Kete;
Core Material: Silicon Steel Sheet;
Winding Material: Copper/Aluminum;
Taping Range: ±2*2.5%;
Voltage Regulator: 5 Steps;
Standard: IEC60076,GB1094;
Insulation Class: a;
Frequency: 50Hz/60Hz;
Coil Structure: Toroidal;
Connection: Yyn0 or Dyn11;
Outline Shape: Vertical Transformer;
Moisture-Proof Method: Sealed;
High Voltage: 10kv;
Low Voltage: 0.4kv;
Capacity: 400kVA 500kVA 630kVA 800kVA 1000kVA 1250kVA;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EE;
Brand: Kete;
Core Material: Silicon Steel Sheet;
Winding Material: Copper/Aluminum;
Taping Range: ±10%;
Voltage Regulator: 2 Steps;
Standard: IEC60076,GB1094;
Insulation Class: a;
Frequency: 50Hz/60Hz;
Coil Structure: Toroidal;
Connection: Yyn0 or Dyn11;
Outline Shape: Vertical Transformer;
Moisture-Proof Method: Sealed;
High Voltage: 35kv;
Low Voltage: 0.4kv;
Capacity: 2000kVA;
Voltage Regulation Method: Oltc;
|
Application: Power;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Vke;
Frequency: 50/60Hz;
Material: Copper/Aluminum;
Capacity: 50kVA;
Hv: 13.62/7.62kv;
|