| Specification |
After-sales Service: 1y;
Warranty: 1y;
Appliance: Trace Impurity Analysis;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Three;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Food Analysis;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Wavelength Range: 190-700nm;
Measurement Method: Chromatography;
Light Source: Deuterium Lamp/Tungsten Lamp;
Instrument Type: UV Detector;
Place of Origin: China;
Size: 400mm * 300mm * 180mm;
Power Supply: 100-240V,50-60Hz,80W;
Application: Food/Agricultural Products, Chemical Industry, etc;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: FID;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Control Range: Room Temperature +5 ~400℃;
Accuracy: ±0.1℃;
Programmed Temperature Ramp: 8;
Heating Rate: 0.1°~-40℃/Min;
Actual Temperature Error: <0.5℃;
Maximum Operation Temperature: 400℃;
Application: Wastewater, Chemical, Pharmaceutical, Hospital, Fo;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: FID;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Control Range: Room Temperature +5 ~400℃;
Accuracy: ±0.1℃;
Programmed Temperature Ramp: 8;
Heating Rate: 0.1°~-40℃/Min;
Actual Temperature Error: <0.5℃;
Maximum Operation Temperature: 400℃;
Application: Wastewater, Chemical, Pharmaceutical, Hospital, Fo;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Medical Research;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Flow Range: 0.001-10ml/Min(Set Step 0.001ml/Min);
Flow Accuracy: ≤±0.25%(0.001-10ml/Min);
Flow Precision: Rsd<0.05%;
Working Pressure: 42.0 MPa;
Gradient: 2 or 3;
Dimension: 400mm*300mm*180mm;
Power Supply: AC 110V/220V,50Hz/60Hz;
Material: 316L;
|