| Specification |
After-sales Service: Standard;
Warranty: Standard;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Fuel Consumption Rate: ≤205g/Kw·H;
Intake Method: Turbocharged;
Maximum Torque Range: 1200 ~ 1500 Rpm;
Cylinder Diameter: 130mm;
Single Cylinder Displacement: 13.0 L;
|
After-sales Service: 24 Hours Online;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Power: 200kw;
Frequency: 50Hz;
Weight(Kg): 1900;
Generator Brand: Shanghai Diesel Engine;
|
After-sales Service: 24 Hours Online;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500rpm, 1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Power: 200kw;
Frequency: 50Hz;
Weight(Kg): 1900;
Generator Brand: Shanghai Diesel Engine;
|
After-sales Service: Yes;
Warranty: 2 Years;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Winding: 100% Copper Wire;
Pole: 4 Poles;
Bearing: Single/Double Bearing;
Frequency: 50Hz/60Hz;
Protection Class: IP23;
Stator Connection: Series Star;
Stator Winding: 311;
Insulation Class: Class H;
High Temperature Resistance: 180℃;
Duty: Continuous(S1);
PF: 0.8;
Power: 50kVA;
Voltage: 400V;
Wire: Copper;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Engine: Cummins;
Alternator: Stanford;
Controller: Smartgen, Deepsea...;
Starting Method: Electric Start;
Power: 8kw - 32kw;
ATS: Optional;
Color: as Per Request;
Frequency: 50Hz/60Hz;
Voltage: 400V 380V;
|