| Specification |
After-sales Service: Provide Timely and Accurate Online After-Sales Ser;
Warranty: 1 Year;
Display: LCD;
Appliance: Biochemistry, Laboratory;
Portable: Portable;
Type: Total Nitrogen Tester;
Weight: 9.1kg;
Power: 36W;
Parameters: Total Nitrogen;
Model No.: Erun-Sp9-N4;
|
After-sales Service: Onsite and Remote Guidance;
Warranty: 1or 2 Years Free Warranty Longlife Service;
Display: LCD Touch Screen;
Portable: Portable;
Type: Dga;
Screen Display: 7-Inch Color Touch Screen;
Display Accuracy: 0.1oc;
Oven Lift Rate: Any Stage Platform Program Temperature Rise, up to;
Repeatability of Temperature Program: Less Than 1%;
(Fid) Maximum Operating Temperature: 400 Oc;
(Fid) Detection Limit: 5*10-12g/S (N-Hexadecane);
(Fid) Baseline Noise: Less 2*10-14A;
(Fid) Dynamic Linear Range: 10 7;
(Tcd) Baseline Noise: Less 10UV;
(Tcd) Maximum Use Temperature: 300 Oc;
(Tcd) Sensitivity: S Value Higher Than 9000mv.Ml/Mg (Benzene);
(Tcd) Baseline Drift: Less 50UV/30min;
Chromatographic Column: One for Measuring H2, Co, CO2, One for Measuring C;
Special Tools and Consumables: Epgc-Smart;
Key Words: Transformer Oil Gas Chromatography Analyser;
|
After-sales Service: Onsite and Remote Guidance;
Warranty: 1or 2 Years Free Warranty Longlife Service;
Display: LCD Touch Screen;
Portable: Portable;
Type: Dga;
Screen Display: 7-Inch Color Touch Screen;
Display Accuracy: 0.1oc;
Oven Lift Rate: Any Stage Platform Program Temperature Rise, up to;
Repeatability of Temperature Program: Less Than 1%;
(Fid) Maximum Operating Temperature: 400 Oc;
(Fid) Detection Limit: 5*10-12g/S (N-Hexadecane);
(Fid) Baseline Noise: Less 2*10-14A;
(Fid) Dynamic Linear Range: 10 7;
(Tcd) Baseline Noise: Less 10UV;
(Tcd) Maximum Use Temperature: 300 Oc;
(Tcd) Sensitivity: S Value Higher Than 9000mv.Ml/Mg (Benzene);
(Tcd) Baseline Drift: Less 50UV/30min;
Chromatographic Column: One for Measuring H2, Co, CO2, One for Measuring C;
Special Tools and Consumables: Epgc-Smart;
Key Words: Transformer Oil Gas Chromatography Analyser;
|
After-sales Service: Online Helps, Installation Helps and Training;
Warranty: 1year;
Portable: Non Portable;
Testing Standard: ASTM D1500;
Power Supply: 220V, 50Hz, Single Phase or Customized;
Oils Can Be Analyzed: Petroleum, Transformer Oil, Diesel Fuel, etc.;
|
Appliance: Liquid;
Portable: Non Portable;
Type: Multi Parameter Water Quality Sensor;
Main Body Information: Support up to 6 Sensor Access, 1 Central Cleanin;
Output: Supports RS-485, Modbus Protocol;
Cleaning Brush: Yes/Standard Configuration;
Full Load Power Consumption: 0.8W(Non Wiping), 2W(Wiping);
IP Range: IP 68;
Material: POM, Titanium Alloy, Anti-Fouling Copper;
|