| Specification |
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Ceramics;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Accuracy: ±1.5c;
Tube Diameter: 8/10/16/22/25mm or Customized;
Type: S/B/R;
Usage: Industrial;
Wire Diameter: 0.3,0.4,0.5mm or Customized;
Tube Material: 99% Ceramic Tube;
Wire Material: Platinum Rhodium;
Temperature: 0-1800degree;
|
Installation Type: Customize;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Customize;
Material: Customize;
Measuring Medium: Temperature;
IP Rating: Customized;
Customized: Customized;
Tolerance: 1%~ 5%;
Resistance: 1K ~ 1m Ohms;
B Value: 3380, 3435, 3950, 3977 /Customize;
Temperature Range: Customized According to Customer Usage;
Wire Length: Customize;
|
Installation Type: DIN35 Rail-Mounted;
Sensing Type: Thermocouple;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Ceramics;
Measuring Medium: Humidity;
IP Rating: IP20;
Customized: Customized;
Input Type: PT100 Input / PT1000 Input;
Accuracy: 0.05%;
Temperature Drif: ± 30 Ppm / ℃;
Input Temperature Rang: (1) PT100,-200~400℃;
Ad Conversion Rate: 5 Sps;
Common Mode Rejection: 120 dB;
Normal Mode Rejection: 60 dB;
Communication: RS-485 Protocol or RS-232;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Ceramics;
Measuring Medium: Humidity;
IP Rating: IP20;
Customized: Customized;
Typical Application: Temperature Signal Measurement/Monitoring/Control;
Typical Application1: RS-485 Remote I / O, Data Acquisition;
Typical Application2: RS-232/485 Bus Industrial Automation Control Syste;
Typical Application3: Industrial Field Signal Isolation and Long-Term Tr;
Typical Application4: Medical, Industrial Product Development;
Typical Application5: Various Types of Thermocouple Signal Acquisition;
Accuracy: 0.1% ( Not Contains Cold Junction Sensor Error);
|
Installation Type: Customize;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Customize;
Material: Customize;
Measuring Medium: Temperature;
IP Rating: Customized;
Customized: Customized;
Tolerance: 1%~ 5%;
Resistance: 1K ~ 1m Ohms;
B Value: 3380, 3435, 3950, 3977 /Customize;
Temperature Range: Customized According to Customer Usage;
Wire Length: Customize;
|