Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single or Three;
Operation Condition: Electronic, Instrument, Lighting;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Exterior Material: PBT Resin UL Flame Retardant Ra;
Dielectric Strength: 1000mohms @ 500 VDC;
Internal Structure: Epoxy;
Rated Frequency: 50-400kHz;
Operating Temp: -25 C~+55 C;
Isolation Voltage: 2500 Vrms for 1 Minute;
Surge Withstand: 5000V;
Rated Load Resistance: 100K Ohms;
Accuracy Class: 0.1 0.2;
|
Application: Current Detect;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Outline Size: 39*71*46;
Hole Size: 24;
Tolerance: ±1;
Accuracy: 1.0%;
Loop Count: 1 Loop;
Rated Frequency: 50~60Hz;
|
Application: Current Detect;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Outline Size: 39*71*46;
Hole Size: 24;
Tolerance: ±1;
Accuracy: 1.0%;
Loop Count: 1 Loop;
Rated Frequency: 50~60Hz;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Capacity: 10-35kv;
Standard: ISO;
Material: Epoxy Resin;
Coil Number: 2;
Coil Structure: Copper;
Product Name: Mutual Inductor;
Winding Material: Copper;
Frequency: 50/60 Hz;
Rated Secondary Voltage: 100;
Input Voltage: 6kv, 10kv, 35kv;
Output Voltage: 110V;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Input Current (AC): 10mA~5A;
Rated Output (AC): 0~1V or 0~5mA;
Linear Range: 5%~120%;
Voltage Level: 0.4/0.66/0.72kv;
|