| Specification |
Connectors: USB;
Test Mode: Point Test;
Usage: Network Cable Tester, HDMI Cable Tester, Audio Cable Tester, Dead and Running Cable Identification;
Test Region: Forming Cable;
Customized: Non-Customized;
Application: Dead and Running Cable Identification;
Transmitter Output: Direct Connection Output, Clamp Coupling Output;
Transmitter Output Frequency: 640Hz (Complex Frequency), 1280Hz (Complex Frequen;
Receiver Input: Soft Flexible Clamp;
Active Frequency: 640Hz,1280Hz;
Power Frequency: 50Hz/60Hz;
Cable Identification Mode: Soft Flexible Clamp;
Power Frequencies Measurement: Range AC 1-1000A,Accuracy +/-3%;
HMI: 800X480 LCD,Size 121X76mm;
Built-in Battery: 2 X 18650 Li-on Batteries, Standard 3.7 V,6.8 Ah;
|
Test Mode: Point Test;
Usage: Power Cable;
Cable Type: XLPE;
Customized: Customized;
Cable Fault Tester: Epdl-a;
Cable Fault Locator: Epdl-D;
Hv Pulse Generator: Epdl-H;
Burn Through Power: 2048j;
Pulse Amplitude: 100vpp;
Pulse Width: 0.1us and 2us;
Measuring Distance: 60km;
Impact High Voltage: 0~8/16/32kv Three Gears Optional;
High Voltage Divider: Voltage Accuracy Level 1.5;
Built-in Capacitance: 4UF/32kv, 16UF/16kv, 64UF/8kv;
Discharge Power: All 2048j;
Impact Power: 2kVA;
Impact Time: Automatic Impact About 4 Seconds, Manual Impact Ar;
Ambient Temperature: -20~+50degree;
Sound Channel: Maximum Signal Gain: >=80dB;
|
Test Mode: Point Test;
Usage: Power Cable;
Cable Type: XLPE;
Customized: Customized;
Cable Fault Tester: Epdl-a;
Cable Fault Locator: Epdl-D;
Hv Pulse Generator: Epdl-H;
Burn Through Power: 2048j;
Pulse Amplitude: 100vpp;
Pulse Width: 0.1us and 2us;
Measuring Distance: 60km;
Impact High Voltage: 0~8/16/32kv Three Gears Optional;
High Voltage Divider: Voltage Accuracy Level 1.5;
Built-in Capacitance: 4UF/32kv, 16UF/16kv, 64UF/8kv;
Discharge Power: All 2048j;
Impact Power: 2kVA;
Impact Time: Automatic Impact About 4 Seconds, Manual Impact Ar;
Ambient Temperature: -20~+50degree;
Sound Channel: Maximum Signal Gain: >=80dB;
|
Test Mode: Impulse Flashover Method;
Usage: Power Cable Test;
Test Region: 0~35kv;
Cable Type: Shielded;
Power: Electricity;
Customized: Customized;
Color: Yellow;
Input Power Supply: AC 220V, 50Hz;
Output Voltage: DC 0-32kv (Adjustable);
Max.Testing Distance: 5km(Open Wire up to 100km) According to Customer's;
Blind Detection: 1m;
Resolution: 1m;
Power Consumption: 5va;
Environmental Temperature: 0-40degree(Limit Temperature:-10degree-50degree);
|
Connectors: FC, Sc, St;
Test Mode: Real-Time Test;
Usage: Network Cable Tester, Fiber Optic Tester;
Test Region: Sm and mm Test Range;
Cable Type: Optica Fiber and Optical Cable;
Power: Electricity;
Customized: Customized;
Color: Grey and White;
|