| Specification |
Warranty: 1 Year;
Brand: Raythink;
Customized: Customized;
Portable: Non Portable;
Gas: CH4,So2,Freon (R-134A, R-152A) and Other Gases;
Type: Thermal Conductivity Gas Analyzer;
Detector Type: Vox Uncooled Fpa Detector;
Spectral Band: 7~8.5μm;
Netd: ≤20mk(@25°c, F#1.0, 25Hz);
Resolution of Detector: 640×512;
Pixel Size: 12μm;
Focal Length: 25mm Electric Focusing Lenses;
Sensor: 4MP 1/1.8" Progressive Scan CMOS;
Resolution: 2688×1520;
Visible Light Focal Length: 6.5~130mm, 20X;
Horizontal Movement: 360° Continuous, 0.1°~40°/S;
Vertical Movement: -90°~+90°, 0.1°~40°/S;
Preset Point: 256;
Scan Mode: Preset Point/Patrol Inspection Group/Pattern/Linea;
Wiper: Wiper;
Measurement Range: -20℃~+550℃;
|
Brand: HV Hipot;
Customized: Customized;
Portable: Portable;
Gas: sf6;
Type: Stirling Refrigeration Principle;
Measurement method: Auto chilled mirror measurement (Stryn refrigerati;
Mirror surface temperature sensor: PRT-100;
Single sample measurement time: 90 seconds (stable);
Operation temperature: -20 ~ +60 centigrade;
Measurement range: -90 ~ +20 centigrade;
Delivery time: 1 month;
Dimension: 470mm*200mm*400mm;
Accuracy: Better than 0.2℃;
|
After-sales Service: Yes;
Warranty: 1 Years;
Brand: Huazheng;
Customized: Customized;
Portable: Portable;
Gas: Sf6;
Type: Sf6 Gas Analyzer;
Name: Cheap Price Sf6 Gas Water Content Moisture Dew Poi;
Measurement Range: Dew Point: -80~+20ºC;
Precision of Dew Point: ±0.5ºC;
Resolution Ratio: Dew Point 0.1ºC or 0.1ppm;
Repeatability: ±0.5ºC;
Precision and Repeatability: ±0.5%, Have Nothing to Do with The Flow;
Gas Measurement Range: H2s:1 ~ 200ppm;
Work Voltage: 220VAC±10% 50Hz;
Pressure: 0~20bar;
Output Interface: USB1.1 Specification;
|
Brand: HV Hipot;
Customized: Customized;
Portable: Portable;
Gas: SF6;
Type: Electrochemical Gas Analyzer;
Measuring principle: Non-dispersive infrared sensor (NDIR);
Measuring range: double path 0-2000ppmv (resolution 0.1) 0-50ppmv (;
Resolution: 0.1ppmv and 0.01ppmv;
Accuracy: 2%FS;
|
After-sales Service: Yes;
Warranty: 1 Years;
Brand: Huazheng;
Customized: Customized;
Portable: Portable;
Gas: Sf6;
Type: Sf6 Gas Analyzer;
Name: Sf6 Gas Analyzer;
Measurement Range: Dew Point: -80~+20ºC;
Precision of Dew Point: ±0.5ºC;
Resolution Ratio: Dew Point 0.1ºC or 0.1ppm;
Repeatability: ±0.5ºC;
Precision and Repeatability: ±0.5%, Have Nothing to Do with The Flow;
Gas Measurement Range: H2s:1 ~ 200ppm;
Work Voltage: 220VAC±10% 50Hz;
Pressure: 0~20bar;
Output Interface: USB1.1 Specification;
|