| Specification |
Type: Infrared Gas Sensor;
Output Signal Type: Digital Type;
Material: Plastic;
Sensitivity: High;
Customized: Customized;
Measurement Ranges: 0-5%,0-20%,0-60%,0-100%;
Time to 1st Reading: <0.5 Seconds;
Response Time: Flow Dependent;
Readings Per Second: 20/50;
Sample Method: Solid-State LED Ndir Diffusion;
Supply Voltage: 3.25V-5.5V;
Power Consumption (Typ.): [email protected]/[email protected];
Operating Conditions -Temperature: 0℃ to 50℃;
Operating Conditions - Humidity: 0-95% Rh,Non-Condensing;
Storage Conditions - Temperature: -40°C to +70℃;
Ambient Operating Pressure: 500mbar to 2bar;
Sensor Lifetime: >15 Years;
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Customized;
Detection Type: Formaldehyde, Benzene, Alcohol, Smoke, Co and Othe;
Tvoc Range: 0~5000μG/M³;
Formaldehyde Range: 0~5000μG/M³ (Analogue Output);
CO2 Range: 0-5000μG/M³,400~5000ppm;
Minimum Resolution: 0.001 Mg/M³ or 1ppm;
Data Accuracy: 3 Min;
Operating Voltage: DC 3.7~6.0V;
Warm-up Time: Default: 5s;
Output Methods: 0.001 Mg/M³ , 1ppm;
Lifespan: 10 Year (in Air);
Operating Temperature: 0ºC~50ºC;
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Non-Customized;
Detection Type: Formaldehyde, Benzene, Alcohol, Smoke, Co and Othe;
Tvoc Range: 0~5000μG/M³;
Formaldehyde Range: 0~5000μG/M³ (Analogue Output);
CO2 Range: 0-5000μG/M³,400~5000ppm;
Minimum Resolution: 0.001 Mg/M³ or 1ppm;
Data Accuracy: 3 Min;
Operating Voltage: DC 3.7~6.0V;
Warm-up Time: Default: 5s;
Output Methods: 0.001 Mg/M³ , 1ppm;
Lifespan: 10 Year (in Air);
Operating Temperature: 0ºC~50ºC;
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Non-Customized;
Detection Type: Formaldehyde, Benzene, Alcohol, Smoke, Co and Othe;
Tvoc Range: 0~5000μG/M³;
Formaldehyde Range: 0~5000μG/M³ (Analogue Output);
CO2 Range: 0-5000μG/M³,400~5000ppm;
Minimum Resolution: 0.001 Mg/M³ or 1ppm;
Data Accuracy: 3 Min;
Operating Voltage: DC 3.7~6.0V;
Warm-up Time: Default: 5s;
Output Methods: 0.001 Mg/M³ , 1ppm;
Lifespan: 10 Year (in Air);
Operating Temperature: 0ºC~50ºC;
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Customized;
Detection Type: Formaldehyde, Benzene, Alcohol, Smoke, Co and Othe;
Tvoc Range: 0~5000μG/M³;
Formaldehyde Range: 0~5000μG/M³ (Analogue Output);
CO2 Range: 0-5000μG/M³,400~5000ppm;
Minimum Resolution: 0.001 Mg/M³ or 1ppm;
Data Accuracy: 3 Min;
Operating Voltage: DC 3.7~6.0V;
Warm-up Time: Default: 5s;
Output Methods: 0.001 Mg/M³ , 1ppm;
Lifespan: 10 Year (in Air);
Operating Temperature: 0ºC~50ºC;
|