Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 12kv;
Installation Method: Withdrawable;
Rated Frequency: 50/60Hz;
Material: Resin;
Model No.: Jdz12-10r;
Brand Name: Shengsu;
Color: Brown/Red;
Customize: Yes;
Size: Medium;
Coil Structure: Toroidal;
Coil Number: Autotransformer;
Power Factor: Cos=0.8(Lagging);
Surface Creepage Distance: Greater Than 250mm;
Standard: GB/T20840.1 GB/T20840.3;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv, 6kv;
Rated Load: ≤240va;
Cosø: 0.8 (Lag);
Key Words: International Potential Transformer;
Key Word: Instrument Potential Transformer;
Model: Potential Transformers and Current Transformers;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 35kv, 24kv, 17.5kv, 15kv, 10kv, 6kv;
Rated Load: 3000va;
Cosø: 0.8 (Lag);
Key Words: 15kv Potential Transformer Manufacturers;
Key Word: High Voltage Transformer Manufacturers;
Model: PT Transformer;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 33kv, 24kv, 10kv, 6kv;
Rated Load: ≤150va;
Cosø: 0.8 (Lag);
Key Words: Low Voltage Transformer;
Applications: Resin Cast Voltage Transformer 24kv;
Model: Voltage Measurement Transformer;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|
Application: Electronic, Instrument, Position Sensor, Audio;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv, 6kv;
Rated Load: ≤100va;
Cosø: 0.8 (Lag);
Key Words: Dry Type Transformer Manufacturer;
Key Word: Dry Type Transformers;
Model: Dry Transformer;
Phase Number: Single;
Rated Frequency: 50Hz or 60Hz;
Rated Insulation Level: 12/42/75kv, 7.2/32/60kv;
Class of Pollution: II;
|