| Specification |
Classification: Medical Diagnosis;
Type: Infrared Thermometer;
Group: All;
Display Precision: 0.1;C/;F;
Rated Output Range: 32 ;C-43 ;C;
Weight: About 125g (Include Battery);
Executive Standard: GB/T 21417.1-2008;
Period of Use: Five Years;
Power: AAA Battery*2;
Measure Time: 1s;
Auto Power off Time: 30s;
Battery: Aaax2, DC 3V;
Accessory: Manual, AAA Battery X2;
Delivery Time: 20-25 Days After Confirmation;
Sample: Free;
Expected Service Life: 5years;
Mode of Operation: Continuous Operation;
Dimensions: 95X45X149(mm);
|
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor;
Group: All;
Sample Quantity: 32;
Model: Bnp32;
Sample Volume: 20-500;
Processing Volume: 60-1000;
Magnetic Bead Recovery: >98%;
Sample Throughput: 1-32;
Built-in Air Duct: Yes;
Extracting The Difference Between Holes: CV≤3%;
Ultraviolet Irradiation: Yes;
Packing Size(W*D*H)mm: 580*510*700mm;
Gross Weight(Kg): 51kg;
Heating Temperature: 8 Independent Heating Modules;
Oscillating Mixing: Low,Medium and High Third Gears Are Adjustable;
Reagent Type: Magnetic Bead Open Platform;
Extraction Time: 15-40 Min/Round (Depending on The;
|
Classification: Biological Diagnostics;
Type: ESR Analyzer;
Group: All Ages;
Model: Bk-ESR40;
Application: Erythrocyte Sedimentation Rate Analysis;
Erythrocyte Sedimentation Rate Analysis: Infrared Detection;
Analysis Result: Westergren ESR Value(mm/Hour);
Throughput: Maximum 80 Tests/Hour;
Analysis Channels: Oad up to 40 Samples for Analysis at The Same Time;
Loading Type: Load Samples at Any Time, Measure at Any Time;
Analysis Time: 30 Minutes or 60 Minutes Selectable;
Sampling Interval: 3 Min;
Measurement Range: 0~150mm/H;
Temperature Compensation: The Result Is Automatically Corrected to The Resul;
Result Resolution: 1mm/1h and 1mm/2h;
Blood Level Range: 46mm~64mm;
Hct Range: 0.2~1.0;
Repeatability: 0~10mm/H, SD≤1.5mm/H; >10mm/H, CV≤15%;
|
Classification: Imaging Diagnostic Equipment;
Type: Automatic Chemiluminescence Immunoassay System;
Group: All;
Model: Bki1100;
Throughput: 80t/H;
Principle: Magnetic Particle Enzymatic Chemilumines;
Modes of Operation: Random, Batch and Stat;
Separation Method: Magnetic Separation Technology;
Sample Positions: 60;
Reagent Positions: 30 PCS;
Incubation Positions: 50;
Time to 1st Result: 18 Minutes;
Ambient Temp.: 5-40℃;
Calibration Stability: 28 Days;
Calibration Type: 6/7-Point Calibration;
Power Supply: AC110/220V±10%,50/60Hz;
External Size(W*D*H)mm: 1120*735*513mm;
Package Size(W*D*H)mm: 1303*873*854mm;
|
Classification: Biological Diagnostics;
Type: /;
Group: All Ages;
Model: Bk-1200;
Throughput: 800tests/Hour, 1200tests/Hour with ISE(Optional);
Analysis Method: End-Point,Fixed-Time, Rate(Kinetic), Turbidimet;
Sample Positions: 150 Sample Positions;
Reagent Position: 180 Reagent Positions;
Sample Volume: 1-70UL;
Reagent Volume: 10-350UL;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: Refrigerated Tray with Independent Switch;
Washing: Automatic Cuvettes Washing;
Mixer Probe: Independent Stirring;
Stat Function: Yes;
Light Source: 12V/20W Halogen Lamp/Fiber Bragg Grating Optional;
|