| Specification |
After-sales Service: Any Problem, We Will Send 1PCS New for Replacement;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Device Application: Power Analysis, Energy Mete;
Sampling Rate: 8K Samples Per Second;
Harmonic: 52th Max;
Power: 4*AA Battery(Wroking Time: Approx 7 Hours) or USB;
Storage: 1GB SD Card(Max 4GB) (Save Intervals 1mins Defau;
Support Extra Sensor: 3PCS BNC Terminal 333mv CT, 320mvro Current Clamp;
IP Degree of Protection: IP20 Conforming to IEC 60629;
Contractual Warranty: 12months;
Colour: White;
Operating Temperature: -25℃TO +55℃;
Storage Temperature: -40℃ to +85℃;
Humidity Rating: 5 to 95% Rh at 50℃(Non-Condensing);
Pullution Degree: 2;
Overvoltage Categor: III,for Distribution Systems up to 277/480V AC;
Altitude: 3000m Max;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Accuracy Class: Active: Class B (Level 1);
Load Current: 0.4%Ib;
Extreme Working Voltage: 0.8~1.15 Rated Voltage;
Operating Voltage: 0.9un~1.1un;
Rated Voltagelevel: 3X220V/380V;
Current Specification: 3X1.5(6)a, 3X10(40)a, 3X20(80)a;
Baud Rate: 1200BPS~9600BPS;
Communication: RS485/M-Bus/4G;
|