| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 500V AC;
Rated Current: 6-63A;
Rated Residential Rating Current: 30mA 100mA 300mA;
Rated Voltage: 230/400V;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Payment: T/T, L/C or Negotiation;
Trade Term: Fob, EXW, C&F, Fca or Negotiation;
Rated Frequency: 50/60Hz;
Rated Short-Circu: 20,25,31.5,40ka;
Rated Current: 630A,1250A,1600A,2000A,2500A;
Rated Voltage: 12kv, 24kv, 35kv;
Polar Distance: 150mm,180mm,210mm,300mm or Ohter;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Payment: T/T, L/C or Negotiation;
Trade Term: Fob, EXW, C&F, Fca or Negotiation;
Rated Frequency: 50/60Hz;
Rated Short-Circu: 20,25,31.5,40ka;
Rated Current: 630A,1250A,1600A,2000A,2500A;
Rated Voltage: 12kv, 24kv, 35kv;
Polar Distance: 150mm,180mm,210mm,300mm or Ohter;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Payment: T/T, L/C or Negotiation;
Trade Term: Fob, EXW, C&F, Fca or Negotiation;
Rated Frequency: 50/60Hz;
Rated Short-Circu: 20,25,31.5,40ka;
Rated Current: 630A,1250A,1600A,2000A,2500A;
Rated Voltage: 12kv, 24kv, 35kv;
Polar Distance: 150mm,180mm,210mm,300mm or Ohter;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: SF6;
Installation: Open Frame;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Rated Voltage: 11kv/22kv/33kv, 12kv;
Winding Material: Copper\Aluminum;
Rated Current: 630A/1250A;
Material: Epoxy Resin;
MOQ: 1PCS;
|