| Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: OEM;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Power Transmission and Transformation Systems;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: OEM;
Rated Capacity: 315kVA;
Rated Voltage-Primary: 10kv, 6kv;
Rated Voltage-Secondary: 0.4kv and Other;
Rated Frequency: 50Hz;
Cooling: an/Af;
Insulation Temperature Resistance Grade: F;
Free Load: 880W;
Load: 3470W;
Free Load Current: 1.2%;
Size (Lwh): 1200X850X1180mm;
Gross Weight: 1250 Kg;
|
Application: Power, Electronic, Instrument, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: OEM;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EE;
Brand: OEM;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Power Transmission and Transformation Systems;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: OEM;
Rated Capacity: 160kVA;
Rated Voltage-Primary: 10kv, 6kv;
Rated Voltage-Secondary: 0.4kv and Other;
Rated Frequency: 50Hz;
Cooling: an/Af;
Insulation Temperature Resistance Grade: F;
Free Load: 540W;
Load: 2130W;
Free Load Current: 1.6%;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Power Transmission and Transformation Systems;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: OEM;
Rated Capacity: 160kVA;
Rated Voltage-Primary: 10kv, 6kv;
Rated Voltage-Secondary: 0.4kv and Other;
Rated Frequency: 50Hz;
Cooling: an/Af;
Insulation Temperature Resistance Grade: F;
Free Load: 540W;
Load: 2130W;
Free Load Current: 1.6%;
|