| Specification |
Warranty: 1-3years;
Type: Micro-Computer Control Automatic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Automation Type;
Excitation Mode: AC Rotating Exciter;
Rated Voltage: 110V, 220V, 230V, 380V, 400V,440V;
Starting System: 24V DC Electric Start, 12V DC Electric Start;
Frequency: 50/60Hz;
Color: Customizable;
Generator Brand: Stanford, Marathon, Engle, Lleysenma, etc;
|
After-sales Service: Life-Long Maintenance;
Warranty: 1 Years or 1500 Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500-3000rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Cylinder: 4;
Color: Customers' Request;
Rated Voltage: 400V;
Rated Frequency: 50Hz/60Hz;
Power Factor: Cosφ = 0.8 (Lagging);
Rated Current: 90A;
Starting Method: DC24V Electric Motor Startup;
Set Weight: 650kg;
Fuel Consumption (at 100% Load): 158g/Kw·H;
Governer: Mechanical;
Insulation Class: H Class;
Protection Class: IP21;
Connection Method: Three-Phase Four-Wire;
Regulation Method: AVR (Automatic Voltage Regulator);
|
After-sales Service: Life-Long Maintenance;
Warranty: 1 Years or 1500 Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500/1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Cylinder: 6;
Color: Customers Request;
Voltage: 400V/230V;
Rated Frequency: 50Hz/60Hz;
Emission Standard: China III;
Power Factor: Cosφ = 0.8 (Lagging);
Output Current: 900A;
Starting Method: DC24V Electric Start;
Set Weight: 4200kg;
Min Fuel Consumption Rate: 195≤ G/Kwh;
Governer: Electronic Unit Pump(Eup);
Insulation Class: H Class;
Protection Class: IP22;
Connection Method: Three-Phase Four-Wire, Y-Type Connection Method;
Regulation Method: AVR (Automatic Voltage Regulator;
|
After-sales Service: Life-Long Maintenance;
Warranty: 1 Years or 1500 Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500/1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Emission Standard: China II;
Cylinder: 16;
Color: Customers' Request;
Voltage: 400V/230V;
Rated Frequency: 50Hz/60Hz;
Power Factor: Cosφ = 0.8 (Lagging);
Output Current: 2160A;
Starting Method: DC24V Electric Start;
Set Weight: 10000kg;
Fuel Consumption (at 100% Load): 216g/Kwh;
Governer: Electronic;
Insulation Class: H Class;
Protection Class: IP22;
Connection Method: Three-Phase Four-Wire, Y-Type Connection Method;
Regulation Method: AVR (Automatic Voltage Regulator);
|
After-sales Service: Life-Long Maintenance;
Warranty: 1 Years or 1500 Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500/1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Emission Standard: China II;
Cylinder: 16;
Color: Customers' Request;
Voltage: 400V/230V;
Rated Frequency: 50Hz/60Hz;
Power Factor: Cosφ = 0.8 (Lagging);
Output Current: 2160A;
Starting Method: DC24V Electric Start;
Set Weight: 10000kg;
Fuel Consumption (at 100% Load): 216g/Kwh;
Governer: Electronic;
Insulation Class: H Class;
Protection Class: IP22;
Connection Method: Three-Phase Four-Wire, Y-Type Connection Method;
Regulation Method: AVR (Automatic Voltage Regulator);
|