| Specification |
After-sales Service: Avaliable;
Warranty: 1 Year;
Display: Online;
Appliance: Biochemistry;
Portable: Portable;
Type: Turbidity Sensor;
Application: General Freshwater Environment;
Main Material: 316L;
Screw Thread: Upper: NPT3/4, Lower: NPT3/4;
Range: 0-10ntu ,0-100ntu,0-1000ntu,0-4000ntu;
Accuracy: ±1%Fs;
Resolution: 0.01ntu(≤10ntu) , 0.1ntu(>10ntu);
Supply: 7-28VDC;
Output: 4-20mA&RS485 at The Same Time;
Power Consumption: <0.2W;
Operating Temperature: 0-+60℃;
Response Time: 1s;
Pressure Resistance: 0.8MPa;
Ingress Protection: IP68;
|
After-sales Service: Online Support;
Warranty: 1year;
Display: Needle;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Conductivity Meter;
Measuring Range: 0.01~20μS/Cm, 0.1~200μS/Cm, 1~2000μS/Cm, 10~20000μ;
Accuracy: ±1%Fs;
Power Consumption: 0.4W (RS485), 1W (Analog);
Power Supply: DC 10~30V (0~10V Voltage Output Requires 24V DC);
Temperature Compensation: -20~+100℃ (Default Compensation Temperature 25℃);
Electrode Wire Length: 5m (10m, 15m, 20m Can Be Customized);
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Name: Bh-485-Bag Online Blue-Green Algae Sensor;
Power: 24VDC or 220VAC;
Communication: RS485 Modbus;
Protection: IP65;
Temperature Range: 0~60c;
Wireless: Optional;
Blue-Green Algae Range: 100-2,000,000cells/Ml;
pH Range: 0~14pH;
Ammonia Nitrogen Range: 0~1000mg/L;
Conductivity Range: 0~2000ms/Cm;
Dissolved Oxygen Range: 0~20mg/L;
Turbidity Range: 0~4000ntu;
Suspended Solid Range: 0~12000mg/L;
Cod Range: 0~2000mg/L;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Name: Bh-485-Cha Digital Chlorophyll Sensor;
Power: 24VDC or 220VAC;
Communication: RS485 Modbus;
Protection: IP65;
Temperature Range: 0~60c;
Wireless: Optional;
Digital Chlorophyll a Range: 0~500 Ug/L;
pH Range: 0~14pH;
Ammonia Nitrogen Range: 0~1000mg/L;
Conductivity Range: 0~2000ms/Cm;
Dissolved Oxygen Range: 0~20mg/L;
Turbidity Range: 0~4000ntu;
Suspended Solid Range: 0~12000mg/L;
Cod Range: 0~2000mg/L;
|
After-sales Service: Online Support;
Warranty: 1year;
Display: Needle;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Conductivity Meter;
Measuring Range: 0.01~20μS/Cm, 0.1~200μS/Cm, 1~2000μS/Cm, 10~20000μ;
Accuracy: ±1%Fs;
Power Consumption: 0.4W (RS485), 1W (Analog);
Power Supply: DC 10~30V (0~10V Voltage Output Requires 24V DC);
Temperature Compensation: -20~+100℃ (Default Compensation Temperature 25℃);
Electrode Wire Length: 5m (10m, 15m, 20m Can Be Customized);
|