| Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Lbs;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Indoor Load Breaker Switch;
Keywords: Indoor Load Breaker Switch;
Product Model: Fn3 Fn5 Fn7;
Rated Voltage: 10/12kv;
Rated Current: 630A/400A;
Dynamic Stable Current (Peak Value): 50ka/31.5ka;
Short Circuit Making Current: 50ka/31.5ka;
Rated Frequency: 50Hz;
Rated Power Frequency Withstand Voltage: 42kv/48kv;
Rated Lightning Impluse Withstand Voltag: 75kv/85kv;
Rated Transfer Current: 1000A;
Motor Operating Power Supply Voltage: AC/DC 110/220V;
Mechanism Life: 10000 Times;
MOQ: 1 Piece;
OEM & ODM Custom: Accept;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Manual Motor Starter;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Current: AC-3 Type Three-Phase;
Control: Button Control or Switch Control;
Standard: En/IEC60947.1/60947.2/60947.4.1;
ICU Breaking Capacity: 30ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Moulded Case Circuit Breaker;
Poles Number: 3p 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Working Current: 16A to 800A;
Production Standard: IEC60947-2;GB14048.2;
Rated Working Voltage: 690V and Below;
ISO: ISO9001 ISO14001;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Moulded Case Circuit Breaker;
Poles Number: 3p 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Working Current: 100A to 630A;
Production Standard: IEC60947-2;GB14048.2;
Rated Working Voltage: 690V and Below;
ISO: ISO9001 ISO14001;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Model No: Knm1-630;
Strandards: IEC 60947;
Rated Current: 10-800A;
Frequency: 50/60Hz;
|