| Specification |
Classification: Biochemical Apparatus;
Type: Defibrillator;
Group: Adult;
Defibrillator: Defibrillator Monitor;
|
Model: Bke-B;
Test Items: K+, Na+, Cl-;
External Size(W*D*H): 390*200*434mm;
Sample: Serum, Plasma, Whole Blood, Cerebrospinal Fluid an;
Measuring Speed: ≤25s;
Analysis Method: Ion Selective Electrode (ISE);
Sample Volume: 60~150UL;
Sample Position: 30 Sample Positions, 5 Emergency Positions, 2 QC P;
Injection Mode: Manual or Automatic Injection Can Be Selected;
Storage: up to 50,000 Test Results;
Printer: Build-in Thermal Printer;
Interface: RS232 Port for Lis;
Display: 7-Inch High-Definition Touch Screen;
Language: Chinese and English, Other Languages Can Be Custom;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Biochemistry Analyzer;
Group: All;
Model: Bk-400;
Throughput: 400tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Sample Positions: 60 or 90 Sample Positions, Built-in Barcode Syst;
Reagent Positions: 45 Reagent Positions;
Probewashing: Automaticwashing Interior and Exterior;
Reagentcooling: Refrigerated Tray with Independent Switch;
Cuvettes: 120 Reusable Cuvettes,Optical Length 6mm;
Mixerprobe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
Light Source: 12V/30W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
Absorbance: 0~3.0ABS;
|
Classification: /;
Type: /;
Model: Bk-EL10c;
Measurement Channel: Vertical 8 Optical Channels;
Plate Type: 96-Well Microplate;
Wavelength Range: 400 ~ 750nm;
Filter: Standard 5 Wavelengths of 340, 405, 450, 492, 630n;
Reading Ravnge: 0.000 ~ 4.000ABS;
Linear Range: 0.000 ~ 3.500ABS;
Resolution: 0.0001ABS;
Repeatbility: CV≤1.0%;
Stability: ≤±0.003ABS;
Vibration Plate Function: 5 Kinds of Vibration Plate Function, Adjustable 0~;
Incubation Function: Temp. Range: Rt +4c~50°C;
Instrument Size(W*D*H): 495*340*370mm;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Group: Infants and Young Children;
Measuring Method: Light Reflection;
Light Source: Xenon Flash;
Display: LCD;
Measuring Range: 0.0 -29.9mg/Dl(0.0~425 Mol/L);
Indication Error: 00-15±1(Mg/Dl): 16-25±1.5(Mg/Dl);
Measuring Accuracy: Rsd<2%;
Battery: 4 Triple a Rechargeable Nickel-Metal Hydride Batte;
Measuring Times: 800 Times After Each Full Charge;
Measuring Units: Mg/Dl; Pmol/L;
Measuring Averages: 2-5 Sets;
Calibration Plate: White Screen 00.0 or 00 1mg/Dl; Yellow Screen 20.0;
Working Temp: 10-30t;
Working Relative Humidity: £80%;
Working Atmospheric Pressure: 75kpa-106 Kpa;
Power Supply: Input: AC220V 50Hz; Output: DC6.0V 0.5A;
|