| Specification |
Classification: Clinical Urodynamic Analyzer;
Type: Urodynamic Detection System;
Group: All;
Material: High Tech Materials;
Function: Clinical Analysis Instrument;
Product Category: Medical Diagnosis Equipment;
Product: Clinical Urodynamic System;
Pressure Measuring Range: Pressure: -50CMH20(-4.9kpa)~200CMH20(19.6kpa) Erro;
MOQ: 1PC;
|
Classification: Biological Diagnostics;
Type: Elisa Processor;
Group: Middle-aged and Old;
Model: Biobase 2000;
Sample Rack: 552 Sample Positions(Tubes 13mm);
Primary Sample Tubes: 12*75mm;
Dispensing System: 2 Aspirating-Dispensing Probe( X-Y-Z Movement);
Removable Trays: Modular Racks to Hold Calibrators, Controls and Re;
Dispensing Time: 4 Minutes to Whole 96 to Microplates;
Spectral Range: 400-700nm;
Temperature Range: Rt to 45 °C;
Temperature Accuracy: ±0.5°C;
Temperature Fluctuation: ±0.5°C;
Washing System: Two 8 Nozzle Manifolds, One to Dispense and The Ot;
Photometric Range: 0.000 ~3.000 Od;
Temperature: 10~30;
Optical Filters: 2 Precision Filters (450,630nm); 2 More on Request;
Software System: Windows 7;
|
Classification: Biological Diagnostics;
Type: Blood Coagulation Analyzer;
Group: All People;
Test Principle: Optical Colorimetry;
Test Items: PT, Aptt, Tt, Fib;
Test Channel: 2(Can Test Different Projects at The Same Time);
Wavelength: 470nm;
Sample Incubation Position: 12;
Reagent Incubation Position: 5;
Detection Position Temperature: 37.0±1.0°c;
Incubation Position Temperature: 37.0±1.0°c;
Incubation Time: 1~999s;
Reaction: 1~99s;
Reagent Dosage: Minimum Dosage 20μl;
Sample Volume: 20μl~40μl;
Display: 5-Inch High-Definition Color Touch Screen;
Storage: 20,000 Results Storage;
Communication Interface: RS232 Serial Interface, Support Lis System;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Model: Bk-280;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 49 Sample Positions;
Reagent Position: 56 Reagent Positions;
Sample Volume: 2~70UL;
Reagent Volume: 20~350UL;
Probe: Coating, with Anti-Collision Function, Liquid Leve;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Software: Windows 7/8/10, Lis System Available;
Interface: LAN Port Access;
Printer: External, Multiple Reporting Mode Available;
Temperature: 10~30ºC;
Humidity: 30-80%;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Product Portable Pulse Oximeter;
Group: All;
Display: LED;
Patient Range: Adult,Child Andneonate;
Measurement Range: 35% ~99%;
Resolution: 1%;
Accuracy: 2% (70% ~ 99%) ;Unspecified (0% ~69%);
Pulse Rate: Measurement Range:30bpm ~ 250bpm;
Pulse Rate Resolution: 1bpm;
Pulse Rate Accuracy: 2bpm;
Temperature: Channel: 1;
Input: Body Surface Thermal-Sensitive Resistor Temperatur;
Input Range: 0~50 Degree;
Input Resolution: 0.1 Degree;
Input Accuracy: 0.2 Degree;
Power Supply: Common 1.5V AA Alkaline Batteries;
Standard Accessories: Oximeter Main Unit, Adult Finger SpO2 Sensor;
|