| Specification |
Type: Strength Testing Machine;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Weight: Approx. 48 Kg;
Power Source: AC220V;
Usage: Paper Testing Instrument;
Design Criteria: Tappi-T472; T808, T810, T811, T818;
Ring Crush Sample: 152*12.7 mm;
Edge Crush Sample: 25*100 mm;
Test Item: Rct, Ect, Fct, Pat, Cmt, CCT;
Capacity (Optional): 10, 20, 50, 100, 200 Kg;
Resolution: 1/100,000;
Precision: < 0.5%;
Delivery Time: 15 Days After Receive The Deposit;
|
Max Diameter of Workpiece: Flame Spread Tester;
Mass Scope of Workpiece: <900kg;
Type: Material Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC220V;
Oil Cylinder Position: Na;
Item Name: ISO5658-2 Radiant Panel Flame Spread Tester;
Name: Imo Flame Spread Apparatus;
Test Standard: ISO5658-2, ASTM E1317, Imo Resolution a. 653(16);
Application 1: Evaluate Combustion of Building Material;
Application 2: Measures Spread Rate of Flame;
Exhaust: 0.01 /S;
Warranty Period: One Year;
Power Supply: 220V, 50Hz;
Test Results 1: Heat for Ignition(Mj/M) and Sustained Burning;
Test Results 2: Cfe (Kw/M2), Total Heat Release (Kw) and So on;
|
Type: Direct Shear Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 1;
Load Way: Mechanical Load;
Loading Method: Dynamic Load;
Display: Needle;
Control: Manual Control;
Weight: 0-100Kg;
Power Source: AC220V;
Oil Cylinder Position: Under;
Vertical Load: 400kpa Max;
Pressure Grade: 00kpa, 200kpa, 300kpa, 400kpa;
Lever Ration: 1 : 12;
Shear Box: 4;
Horizontal Shear Force: 1.2kn;
Specimen Size: 30cm2 X 2cm (H);
Speed Ratio: 2.4mm/Min. 0.8mm/Min. 0.1mm/Min. 0.02mm/Min;
|
Max Diameter of Workpiece: Flooring Radiant Panel Fire Tester;
Mass Scope of Workpiece: <900kg;
Type: Material Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC220V;
Oil Cylinder Position: Na;
Item Name: ISO9239-1 Flooring Radiant Panel;
Name: ISO9239-1 Flooring Radiant Panel;
Application I: Determine Burning Behaviour of Floorings;
Application II: Determine Flame Spread at a Heat Flux Level;
Test Standards: ISO9239-1, ISO9239-2, ASTM E648, ASTM E970,Nfpa253;
Heat Flux Level: 25kw/M2;
Size: 1900mm (W) X 750mm X (H) X 2120mm (D);
Power Supply: 220V, 50Hz;
Warranty: 1 Year;
After Sale Service: Supply Installation and Commissioning Service;
|
Max Diameter of Workpiece: Critical Radiant Flux Tester;
Mass Scope of Workpiece: <900kg;
Type: Material Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC220V;
Oil Cylinder Position: Na;
Item Name: ISO9239-2 Flooring Flame Spread Tester;
Name: Floor Covering System Critical Radiant Flux Tester;
Application I: Test Critical Radiant Flux of Floor Coverings;
Application II: Determine Flame Spread at a Heat Flux Level;
Test Standards: ISO9239-1, ISO9239-2, ASTM E648, ASTM E970, Nfpa25;
Heat Flux Level: 25kw/M2;
Size: (W)1, 900mm * (D)750mm * (H)2, 120mm;
Power Supply: 220V, 50Hz;
Warranty: 1 Year;
After Sale Service: Supply Installation and Commissioning Service;
|