| Specification |
After-sales Service: Changing or Refunding;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Diesel Fuel, Fuel Oil;
Size: DN10~DN200 or Customize;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Oil;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Medium Temperature: -20℃~80℃; -20℃~200℃; etc.;
Pressure Rating: 1.6MPa, 2.5MPa, 4.0MPa, 6.3MPa, or Customized;
Body Material: Cast Iron, Cast Steel, Stainless Steel, etc.;
Viscosity: 0.6~2MPa.S, 2~200MPa.S, 200~1000MPa.S, 1000~2000;
Connection Way: Flange, Thread;
|
After-sales Service: Video Guidance;
Warranty: 18 Months;
Accuracy: 0.25% 0.5% 1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Liquid, Steam;
Size: DN15-DN2000;
Sensor: Throttling Gear;
Application: Industrial Production;
Type: Differential Pressure Flowmeter;
Measuring Media: Liquid, Gas, Steam, Other Mixed Media;
Measuring Principle: Differential Pressure Principle;
Measurement Object: Closed Pipeline;
According to National Standards: GB/T2624-93 Design and Manufacture;
According to The National Verification R: Jjg 640-94 Was Tested;
Pressure Extraction Method: Angle Contact Pressure, Flange Pressure, D-D/2 Pre;
Nominal Pressure: 0.6~32(MPa);
Medium Temperature: -10℃~+450℃;
Straight Pipe Length Requirement and Thr: in Accordance with Relevant Provisions of GB/T2622;
|
After-sales Service: Video Guidance;
Warranty: 18 Months;
Accuracy: 0.25% 0.5% 1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas, Liquid, Steam;
Size: DN15-DN2000;
Sensor: Throttling Gear;
Application: Industrial Production;
Type: Differential Pressure Flowmeter;
Measuring Media: Liquid, Gas, Steam, Other Mixed Media;
Measuring Principle: Differential Pressure Principle;
Measurement Object: Closed Pipeline;
According to National Standards: GB/T2624-93 Design and Manufacture;
According to The National Verification R: Jjg 640-94 Was Tested;
Pressure Extraction Method: Angle Contact Pressure, Flange Pressure, D-D/2 Pre;
Nominal Pressure: 0.6~32(MPa);
Medium Temperature: -10℃~+450℃;
Straight Pipe Length Requirement and Thr: in Accordance with Relevant Provisions of GB/T2622;
|
After-sales Service: 1 Year;
Warranty: 2 Years;
Accuracy: ≤±0.1%;
Main Application: Oxygen;
Sensor: Tube/Flange;
Application: Transportation;
Type: Probe Type Flow Meter;
Measuring Media: O2;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
|
After-sales Service: 1 Year;
Warranty: 2 Years;
Accuracy: ≤±0.1%;
Main Application: Oxygen;
Sensor: Tube/Flange;
Application: Transportation;
Type: Probe Type Flow Meter;
Measuring Media: O2;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
|