| Specification |
Type: Temperature Sensor Probe;
Anti-theft Alarm System Approach: Passive;
Anti-Theft Alarm System Type: Linear Heat Detection Cable;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Anti-Theft Alarm System Distance: Linear Heat Detection Cable (Line Type Heat Sensit;
Types of Smoke Detectors: Linear Heat Detection Cable;
Infrared Sensor Probe Type: Infrared Temperature Sensor;
Infrared Sensor Installation: Linear Heat Detection Cable;
Combustible Gas Detector Model: Linear Heat Detection Cable;
Color: Red/White;
Detector Type: Cable-Type, Restorable, Fixed-Temperature, Detecti;
Fixed-Temperature Alarm Point: 85°C;
Maximum Operating Length: 200m;
Thermal Cable Core Insulation Resistance: ≥100MΩ;
Operating Voltage: DC24V, Allowable Rang: DC20V~DC28V;
Standby Current: ≤15mA;
Alarm Current: ≤25mA;
Overcurrent Protection Trip Current: >50mA;
Operating Environment: Suitable Humidity ≤ 95% (Non-Condensing);
Suitabletemperature: -40°C to +50°C;
Enclosure Protection Rating: IP66;
Compliance Standard: GB 16280-2014;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Smoke Detector;
Operating Voltage: 9V Battery;
Standby Current: ≤20uA;
Alarm Current: ≤30mA;
Indicator: Two LEDs;
Alarm Decibel: 85dB;
Smoke Sensitivity: 0.15±0.03dB/M;
Detecting Area: 40-60m²;
Test Button: Yes;
Wireless Output: Optional;
Dimention: 105mm X 55mm;
Operating Temperature: -10℃ to +50℃;
Operating Humidity: ≤95% RH;
Usage: Fire Detection, Smoke Detection, Fire Alarm;
Application: Home, Office, Apartment, Hotel, Bank etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Wireless Smoke Alarm Detecor;
Operating Voltage: 9V Battery;
Standby Current: ≤10uA;
Alarm Current: ≤35mA;
Indicator: Two LEDs;
Alarm Decibel: 85dB;
Sensor Type: Infrared Photoelectric Diode;
Detecting Area: 20-40m²;
Test Button: Yes;
Wireless Output: Optional;
Dimention: 109mm X 51mm;
Operating Temperature: -10℃ to +50℃;
Operating Humidity: ≤95% RH;
Usage: Fire Detection, Smoke Detection, Fire Alarm;
Application: Home, Office, Apartment, Hotel, Bank etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Wireless Smoke Alarm Detecor;
Operating Voltage: 9V Battery;
Standby Current: ≤10uA;
Alarm Current: ≤35mA;
Indicator: Two LEDs;
Alarm Decibel: 85dB;
Sensor Type: Infrared Photoelectric Diode;
Detecting Area: 20-40m²;
Test Button: Yes;
Wireless Output: Optional;
Dimention: 109mm X 51mm;
Operating Temperature: -10℃ to +50℃;
Operating Humidity: ≤95% RH;
Usage: Fire Detection, Smoke Detection, Fire Alarm;
Application: Home, Office, Apartment, Hotel, Bank etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Wireless Smoke Alarm Detecor;
Operating Voltage: 9V Battery;
Standby Current: ≤10uA;
Alarm Current: ≤35mA;
Indicator: Two LEDs;
Alarm Decibel: 85dB;
Sensor Type: Infrared Photoelectric Diode;
Detecting Area: 20-40m²;
Test Button: Yes;
Wireless Output: Optional;
Dimention: 109mm X 51mm;
Operating Temperature: -10℃ to +50℃;
Operating Humidity: ≤95% RH;
Usage: Fire Detection, Smoke Detection, Fire Alarm;
Application: Home, Office, Apartment, Hotel, Bank etc.;
|