| Specification |
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Single Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise Automation Type;
Rated Output (Kw/kVA): 3-2400kVA;
Rated Voltage (V): 230/400V;
Rated Current(a): 9-4061A;
Rated Frequency: 50/60Hz;
Power Factor: 0.8lagging;
Rated Power (Kw/1500rpm): 3-2400kVA;
Cylinder Number: 3,4,6,8,12cylinders;
Net Weight of Set (Kg): Specified;
Dimension of Set (mm): 1485*700*1000mm~7300*2440*2800mm;
Product Name: Silent Type Diesel Generator;
|
After-sales Service: on-Site Maintenance/Online Guidance;
Warranty: 12 Months or 1000h;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500rpm, 1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Frequency: 50/60 Hz;
Voltage: 110-480V;
Controller: Deepsea, Smartgen;
Alternator: Leroy Somer, Mecc Alte;
|
After-sales Service: 24 Hours Online Sales;
Warranty: 1 Year or 1000running Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Wind Cooling;
Output Type: AC Three Phase;
Speed: 1500/1800;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Type of Engine: Diesel, Single Cylinder, 4-Cycle Air-Cooled;
Voltage and Frequency V(Hz): 120, 220, 230, 240(at 50/60);
Fuel Tank Capacity: 8hours or More as Required;
Controller: Smartgen, Deepsea;
|
After-sales Service: 24 Hours Online Sales;
Warranty: 1 Year or 1000running Hours;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Wind Cooling;
Output Type: AC Three Phase;
Speed: 1500/1800;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Type of Engine: Diesel, Single Cylinder, 4-Cycle Air-Cooled;
Voltage and Frequency V(Hz): 120, 220, 230, 240(at 50/60);
Fuel Tank Capacity: 8hours or More as Required;
Controller: Smartgen, Deepsea;
|
After-sales Service: on-Site Maintenance/Online Guidance;
Warranty: 12 Months or 1000h;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500rpm, 1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Frequency: 50/60 Hz;
Voltage: 110-480V;
Controller: Deepsea, Smartgen;
Alternator: Leroy Somer, Mecc Alte;
|