| Specification |
After-sales Service: Yes;
Principle: Radar;
Range: 0-15m;
Measurement Accuracy: ±5mm;
Accuracy: ±0.5%Fs;
Kind: Static Pressure;
Structure: Split Type;
Warranty: 3 Year;
Material: PC;
Process Temperature: -40°-80°;
Feature 1: Wireless;
Feature 2: Non-Contact Measurement;
Function 1: Water Level Detector;
Function 2: Water Level Meter;
Function 3: Liquid Meter;
|
After-sales Service: Factory Warranty;
Principle: Ultrasonic;
Range: 0-20m;
Measurement Accuracy: 0.5%;
Accuracy: 0.5%;
Kind: Ultrasonic Wave;
Structure: All in One;
Warranty: 1 Year;
Material: ABS, Ptee(Optional);
Process Temperature: -20-+60;
Customized Support: OEM, ODM;
Output Signal: 4-20mA/0-5V/0-10V;
Communication: RS485;
Measuring Media: Liquid;
Protection Grade: IP65;
Selling Units: Single Item;
Single Gross Weight: 1.500 Kg;
|
After-sales Service: Factory Warranty;
Principle: Radar;
Range: 0.08m-120m;
Measurement Accuracy: ±1mm;
Accuracy: ±1mm;
Kind: Radar;
Structure: All in One;
Warranty: 1 Year;
Material: Aluminum Alloy;
Process Temperature: -20-+60;
Customized Support: OEM, ODM;
Output Signal: 4-20mA/RS485;
Communication: RS485;
Measuring Media: Liquid / Solid;
Protection Grade: IP65;
Selling Units: Single Item;
Single Gross Weight: 1.500 Kg;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Signal Output: Two-Wire 4-20mA Isolated DC Signal Superimposed Wi;
Power Supply: DC 12-45V; Hart;
Winey Value: The Adjustable Range of Electronic Damping Is 0 T;
Fault Alarm: When The Self-Diagnostic Program Detects a Faul;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
|