| Specification |
After-sales Service: warranty;
Warranty: 1 year;
Display: Digital;
Portable: Non Portable;
Appliance: Medical Research, Biochemistry, water;
Measuring Range: 0-14pH;
Temperature Range: -25℃-+100℃;
Pressure Resistance Range: 0~3Bar, 6Bar Max;
Temperature Compensation Type: NTC 2.252K, NTC 5K, NTC 10K, NTC 22K, NTC 30K, PT1;
Factory Slope: Better than 95%;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: -2.00 to 18.00 pH;
pH Resolution: 0.01pH;
pH Accuracy: ±0.01 pH;
pH Calibration Points: up to 3;
pH Standard Recognition: Nist Buffers;
Mv Range: -1999 to 1999 Mv;
Mv Resolution: 1 Mv;
Mv Accuracy: ±0.1%Fs;
Reading Mode: Auto Read, Continuous;
Reading Prompts: Reading, Stable, Locked;
Temp. Compensation: Mtc;
Data Storage: 50 Results Each;
pH Electrode: BNC(Q9);
Power: AC Adapter, 100-240V AC Input, DC9V Output;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: -2.00 to 20.00 pH;
pH Resolution: 0.1,0.01pH;
pH Accuracy: ±0.01 pH;
pH Calibration Points: up to 5;
pH Standard Recognition: Nist, GB, USA and DIN Buffers;
Mv Range: -2000.0 to 2000.0 Mv;
Mv Resolution: 0.1;
Mv Accuracy: ±0.3 Mv or ±0.1%;
Temperature Range: -5 to 110 ℃, 23 to 230 ℉;
Temperature Unit: ℃, ℉;
Temperature Resolution: 0.1;
Temperature Accuracy: ±0.2℃;
Measurement Reading Prompts: Reading, Stable, Locked;
Temp. Compensation: Atc, Mtc;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: -2.00 to 20.00 pH;
pH Resolution: 0.1,0.01,0.001pH;
pH Accuracy: ±0.02 pH;
pH Calibration Points: up to 5;
pH Standard Recognition: Nist, GB, DIN, USA and Merk Buffers;
Mv Range: -2000.0 to 2000.0 Mv;
Mv Resolution: 0.1,0.01m;
Mv Accuracy: ±0.1 Mv or ±0.03%;
Temperature Range: -10 to 135 ℃, 14 to 275 ℉;
Temperature Unit: ℃, ℉;
Temperature Resolution: 0.1;
Temperature Accuracy: ±0.1℃;
Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous;
Reading Prompts: Reading, Stable, Locked;
|
After-sales Service: Technical Support;
Warranty: 1 Year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Display Screen: 3.2 Inch LCD;
Current Output: 4-20mA;
Relays Control: Two Relays;
Protection Grade: IP66;
|