少妇高潮喷水久久,丁香婷婷久久一区二区,中文字幕亚洲区日日骚,欧美婷婷一区二区三区,98新超碰,激情色专线,老司机精品视频。,日日骚AV片日韩不卡,伊人狼人久久网

Underground Cable Fault Locator
US$2,430.00-2,630.00 / Piece
  • Recommend for you
  • What is China Manufacturing Factory Hv Surge Generator 0-35kv 2UF 1250j Underground Tdr Cable Fault Locator Testing Equipment
  • What is High Accuracy Electric Underground Tdr Cable Fault Locator for Rough Distance Measurement
  • What is Highest Quality Tdr Multiple Underground Cable Fault Tester Cable Fault Pre-Locator

What is Lucyelec Testing Equipment Underground Cable Testing Tdr Cable Fault Locator

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Piece US$2,430.00-2,630.00 / Piece

Sepcifications

  • After-sales Service Free Technical Support and Training, 24h Online
  • Warranty One Year Warranty and Long Life Maintenance
  • Usage Tdr Cable Fault Locator
  • Power Electricity
  • Certification CE
  • Customized Non-Customized
  • Color Red
  • Transport Package Standard Export Package
  • Specification 52X42X74 cm
  • Trademark Lucyelec
  • Origin Shaanxi, China
  • Supplier Lucyelec Test Equipment Co., Ltd.
  • Customized Support OEM, ODM, Obm
  • Place of Origin Shanxi, China
  • Model Number Gg502A
  • Product Name Cable Fault Prelocator
  • Function for Underground Rough Distance Measurement Automat
  • Certificate ISO CE
  • Test Method Arc Reflection Method

Product Description

Lucyelec Testing Equipment Underground Cable Testing TDR Cable Fault Locator China factory TEST underground cable fault locator for rough distance measurement automatically 2024 new design Product descriptions from the supplier Overview Product Description GG502A ARC cable fault prelocator ...

Learn More

Underground Cable Fault Locator Comparison
Transaction Info
Price US$2,430.00-2,630.00 / Piece US$3,000.00-10,000.00 / Piece US$3,000.00-10,000.00 / Piece US$3,000.00-6,000.00 / Piece US$3,000.00-10,000.00 / Piece
Min Order 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece
Payment Terms LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment
Quality Control
Product Certification ISO CE - - - -
Management System Certification - - - - -
Trade Capacity
Export Markets South America, Europe North America, Europe, Domestic North America, Europe, Domestic North America, Europe, Domestic North America, Europe, Domestic
Annual Export Revenue - - - - -
Business Model ODM, OEM Own Brand, ODM, OEM Own Brand, ODM, OEM Own Brand, ODM, OEM Own Brand, ODM, OEM
Average Lead Time Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Product Attributes
Specification
After-sales Service: Free Technical Support and Training, 24h Online;
Warranty: One Year Warranty and Long Life Maintenance;
Usage: Tdr Cable Fault Locator;
Power: Electricity;
Customized: Non-Customized;
Color: Red;
Supplier: Lucyelec Test Equipment Co., Ltd.;
Customized Support: OEM, ODM, Obm;
Place of Origin: Shanxi, China;
Model Number: Gg502A;
Product Name: Cable Fault Prelocator;
Function: for Underground Rough Distance Measurement Automat;
Test Method: Arc Reflection Method;
Test Distance: 35km;
Power Consumption: 5va;
Detecting Distance: 0.5mm2≤3km, Other Is 20km;
Positioning Accuracy: ≤±10mm;
Failure Point Insulation Resistance: 0~50mΩ;
Detection Depth: ≤3m;
Rated Power: 3kVA;
Insulation Method:  Epoxy Resin, Oil;
Output Voltage: DC 0~50kv;
Output Current: 60mA;
Test Distance: 35km;
Power Consumption: 5va;
Detecting Distance: 0.5mm2≤3km, Other Is 20km;
Positioning Accuracy: ≤±10mm;
Failure Point Insulation Resistance: 0~50mΩ;
Detection Depth: ≤3m;
Rated Power: 3kVA;
Insulation Method:  Epoxy Resin, Oil;
Output Voltage: DC 0~50kv;
Output Current: 60mA;
Test Distance: 35km;
Power Consumption: 5va;
Detecting Distance: 0.5mm2≤3km, Other Is 20km;
Positioning Accuracy: ≤±10mm;
Failure Point Insulation Resistance: 0~50mΩ;
Detection Depth: ≤3m;
Rated Power: 3kVA;
Insulation Method:  Epoxy Resin, Oil;
Output Voltage: DC 0~50kv;
Output Current: 60mA;
Test Distance: 35km;
Power Consumption: 5va;
Detecting Distance: 0.5mm2≤3km, Other Is 20km;
Positioning Accuracy: ≤±10mm;
Failure Point Insulation Resistance: 0~50mΩ;
Detection Depth: ≤3m;
Rated Power: 3kVA;
Insulation Method:  Epoxy Resin, Oil;
Output Voltage: DC 0~50kv;
Output Current: 60mA;
Supplier Name

Baoding Lucyelec Test Equipment Co., Ltd.

Gold Member Audited Supplier

Kiyu Power Wuhan Co., Ltd

Diamond Member Audited Supplier

Kiyu Power Wuhan Co., Ltd

Diamond Member Audited Supplier

Kiyu Power Wuhan Co., Ltd

Diamond Member Audited Supplier

Kiyu Power Wuhan Co., Ltd

Diamond Member Audited Supplier

宿州市| 博乐市| 徐水县| 习水县| 乌兰察布市| 福清市| 九江市| 吐鲁番市| 昌吉市| 荔浦县| 乌鲁木齐县| 璧山县| 南郑县| 石渠县| 奉节县| 瑞安市| 和平区| 原阳县| 策勒县| 岳西县| 泸定县| 保康县| 云安县| 乌兰县| 韶关市| 确山县| 青田县| 新竹县| 南乐县| 岳普湖县| 丘北县| 通州区| 石城县| 景德镇市| 慈利县| 婺源县| 南京市| 沿河| 凌海市| 永宁县| 湟源县|