| Specification |
Type: Float;
Contact: Contact;
Output Signal Type: Switching Type;
Production Process: Injection;
Feature: Conductor;
Material: PP;
IP Rating: IP68;
Customized: Customized;
Rated Voltage: 250VAC;
Rated Current: 16(8)a;
Working Temperature: 0-70 Degree;
Housing Material: PP;
Protection: IP68;
Working Pressure: Max 1 Bar;
Cable Length: 2 / 3 / 4 / 5 / 8 / 10m or as Request;
|
Type: Floating Ball;
Contact: Contactless;
Output Signal Type: Analog Type;
Production Process: Integration;
Feature: Magnetostrictive;
Material: 304,316L, Hastelloy, Pte or PFA;
IP Rating: IP67;
Customized: Customized;
Stroke Length: Hard Rod: 50 ~ 6000mm;; Flexible Rod: 1000 ~ 2300m;
Data Format: Analog or Modbus Output;
Resolution: 0.1mm;
Repetition Accuracy: ≤ ± 0.01% of Full Scale;
Response Time: 20ms;
Temperature Performance: ≤100ppm/℃;
Dielectric Density: 500~1800kg/M3;
Pressure Bearing Characteristic: 1.6MPa;
Temperature: Ambient Temperature:-30℃ ~ + 70℃; Medium Temperat;
Process Interface: M27X1.5;G3/4;
Electrical Interface: 2PC G1/2;2PC M18*1.5 ;Zg3/4;
Indication Error: ≤ ± 0.05% of Full Scale;
Overvoltage Protection: Max.36VDC;
Other Functions: 5-Point Temperature Measurement;
|
Type: Floating Ball;
Contact: Contactless;
Output Signal Type: Analog Type;
Production Process: Integration;
Feature: Magnetostrictive;
Material: 304,316L, Hastelloy, Pte or PFA;
IP Rating: IP67;
Customized: Customized;
Stroke Length: Hard Rod: 50 ~ 6000mm;; Flexible Rod: 1000 ~ 2300m;
Data Format: Analog or Modbus Output;
Resolution: 0.1mm;
Repetition Accuracy: ≤ ± 0.01% of Full Scale;
Response Time: 20ms;
Temperature Performance: ≤100ppm/℃;
Dielectric Density: 500~1800kg/M3;
Pressure Bearing Characteristic: 1.6MPa;
Temperature: Ambient Temperature:-30℃ ~ + 70℃; Medium Temperat;
Process Interface: M27X1.5;G3/4;
Electrical Interface: 2PC G1/2;2PC M18*1.5 ;Zg3/4;
Indication Error: ≤ ± 0.05% of Full Scale;
Overvoltage Protection: Max.36VDC;
Other Functions: 5-Point Temperature Measurement;
|
Type: Liquid Level Sensor;
Contact: Contact;
Output Signal Type: Switching Type;
Production Process: Normal Wirewound;
Feature: magnet;
Material: SUS304 Stainless steel;
IP Rating: IP67;
Customized: Customized;
Usage: Level Sensor;
Description: float level switch sensor;
Theory: Current Sensor;
Selling Units: Single item;
Output: Switching Transducer;
Switching type: NO;
Mounting Type: float level switch sensor;
|
Type: Floating Ball;
Contact: Contactless;
Output Signal Type: Analog Type;
Production Process: Integration;
Feature: Magnetostrictive;
Material: 304,316L, Hastelloy, Pte or PFA;
IP Rating: IP67;
Customized: Customized;
Stroke Length: Hard Rod: 50 ~ 6000mm;; Flexible Rod: 1000 ~ 2300m;
Data Format: Analog or Modbus Output;
Resolution: 0.1mm;
Repetition Accuracy: ≤ ± 0.01% of Full Scale;
Response Time: 20ms;
Temperature Performance: ≤100ppm/℃;
Dielectric Density: 500~1800kg/M3;
Pressure Bearing Characteristic: 1.6MPa;
Temperature: Ambient Temperature:-30℃ ~ + 70℃; Medium Temperat;
Process Interface: M27X1.5;G3/4;
Electrical Interface: 2PC G1/2;2PC M18*1.5 ;Zg3/4;
Indication Error: ≤ ± 0.05% of Full Scale;
Overvoltage Protection: Max.36VDC;
Other Functions: 5-Point Temperature Measurement;
|