| Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Tissue Embedding Center;
Group: Laboratory;
Product Name: Tissue Embedding Center;
Inverter Compressor: Yes;
Capacity: 6 Liters;
Touch Button: Yes;
Memory Function: Yes;
Set The Displayed Date: Yes;
Display Time: Yes;
Display Temperature: Yes;
Double Filter Protection: Yes;
Preset Range of Wax Melting Tank Tempera: 0-99c;
The Preset Temperature Range of The Hold: 0-99c;
Temperature Control Range of Worktable: 0-99c;
Temperature Control Accuracy: +/-1%;
Power Supply Voltage: AC220V+/-10%;
Cold Table Temperature: Normal Temperature to -20c;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Biochemistry Analyzer;
Group: All;
Model: Bk-400;
Throughput: 400tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Sample Positions: 60 or 90 Sample Positions, Built-in Barcode Syst;
Reagent Positions: 45 Reagent Positions;
Probewashing: Automaticwashing Interior and Exterior;
Reagentcooling: Refrigerated Tray with Independent Switch;
Cuvettes: 120 Reusable Cuvettes,Optical Length 6mm;
Mixerprobe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
Light Source: 12V/30W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
Absorbance: 0~3.0ABS;
|
Classification: /;
Type: /;
Model: Bk-EL10c;
Measurement Channel: Vertical 8 Optical Channels;
Plate Type: 96-Well Microplate;
Wavelength Range: 400 ~ 750nm;
Filter: Standard 5 Wavelengths of 340, 405, 450, 492, 630n;
Reading Ravnge: 0.000 ~ 4.000ABS;
Linear Range: 0.000 ~ 3.500ABS;
Resolution: 0.0001ABS;
Repeatbility: CV≤1.0%;
Stability: ≤±0.003ABS;
Vibration Plate Function: 5 Kinds of Vibration Plate Function, Adjustable 0~;
Incubation Function: Temp. Range: Rt +4c~50°C;
Instrument Size(W*D*H): 495*340*370mm;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Group: Infants and Young Children;
Measuring Method: Light Reflection;
Light Source: Xenon Flash;
Display: LCD;
Measuring Range: 0.0 -29.9mg/Dl(0.0~425 Mol/L);
Indication Error: 00-15±1(Mg/Dl): 16-25±1.5(Mg/Dl);
Measuring Accuracy: Rsd<2%;
Battery: 4 Triple a Rechargeable Nickel-Metal Hydride Batte;
Measuring Times: 800 Times After Each Full Charge;
Measuring Units: Mg/Dl; Pmol/L;
Measuring Averages: 2-5 Sets;
Calibration Plate: White Screen 00.0 or 00 1mg/Dl; Yellow Screen 20.0;
Working Temp: 10-30t;
Working Relative Humidity: £80%;
Working Atmospheric Pressure: 75kpa-106 Kpa;
Power Supply: Input: AC220V 50Hz; Output: DC6.0V 0.5A;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Biochemistry Analyzer;
Group: All;
Average Residue: <1μl;
Number Ofmicroplate: 1- 12 Rows Adjustable;
Cleaninghead: 8 Channels and 12 Channels;
Liquidsuctiontime: 0.1-9.9 Seconds Adjustable, with an Interval of 0.;
Flushingpipeline Time: 0-240 Seconds Adjustable;
Display: 5.0 Inch LCD Screen;
Liquidinjectionchannels: 3 (2 Types of Lotion and 1 Type of Distilled Water;
Cleaningneedleposition: 5 Types Adjustable (Horizontal,Left,Center,Right,B;
Packing Size(W*D*H): 710*510*451mm;
Gross Weight: 23kg;
Microplate Types: 48-Well, 96-Well;
Washing: Automatic Washing, 5 Ways;
Washing The Row: 1 Row Per Time;
Number of Microplate: 1- 12 Rows;
Dispense Precision: CV≤3%;
|