| Specification |
After-sales Service: High Quality After Sale Service;
Warranty: 1 Year;
Accuracy: ±0.6-1%;
Main Application: Nature Gas;
Size: DN25-DN200;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Turbine Flow Meter;
Measuring Media: Gas;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Output Type: RS 485;
Power: 24VDC;
Range Ratio: 1/160;
Body Material: Aluminium Alloy;
Pressure: 1.6MPa;
Temperature: -20-55 Deg C;
|
After-sales Service: Have;
Warranty: 1 Year;
Accuracy: ±1.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Plug-in;
Application: Energy Metering;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Sensor Material: 316L/Hc/Ta/Wc/Pl;
Liner Material: PTFE/PFA/F46/Neoprene/Polyurethane;
Customized Support: OEM, ODM;
Communication: RS-485 /Modbus;
Power Supply: 220VAC/ 24VDC/Battery;
Output: 4-20mA/Pulse/Lora/Nb-IoT;
|
After-sales Service: Changing or Refunding;
Warranty: 1 Year;
Accuracy: 4%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas;
Size: DN15~DN150;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Variable Area Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Temperature: 0~60 ℃;
Pressure Rating: ≤0.6 MPa;
Connection Way: Flange, Threaded, Insertion;
Turndown Ratio: 10:1;
|
After-sales Service: 24 Hours;
Warranty: 1 Year;
Accuracy: up to ±0.04% of Span;
Main Application: Water, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: 0.590-in/0.590-in;
Sensor: Clamp-on/External;
Application: Industrial Production;
Type: Differential Pressure Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Item Name: Rosemount 3051smv Multivariable Transmitter;
Model: 3051smv;
Type Name: Multivariable Transmitter;
MOQ: 1PC;
Rangedown: up to 200:1;
Measurement Range: 2000 Psi (137, 89 Bar) Differential;
Communication Protocol: 4-20 Ma Hart®, Wirelesshart®, Foundation™ Fieldbus;
Process Wetted Material: 316 Sst, Alloy C-276 Tantalum, Gold-Plated 316L S;
Diagnostics: Basic Diagnostics;
Certifications: NSF, Nace™, Hazardous Location;
Static Pressure Type: Absolute/Gage;
Temperature Input: Rtd PT 100, -328 to 1562 °F -200 to 850;
Isolating Diaphragm: 316L Sst Alloy C-276 Tantalum;
Process Connection: 305/306 Integral Manifold T 304 or Amf Manifold;
Housing Style: Aluminum/ Sst;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Diesel Fuel, Fuel Oil;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Model: Fmc-50-Nx-1;
Flow Range: 38-380L/Min;
Repeatability: ≤0.07%;
Max.Pressure: 10bar/150psi;
|