| Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Poles Number: 4;
Rated Insulation Voltage: 1500V;
Rated Thermal Current: 32A;
Rated Impulse Withstand Voltage: 8000V;
Rated Short-Circuit Making Capacity: 1000A;
Solid or Standard: 2.5-6mm2;
Tightening Torque Terminal Screws M4.: 1.2-1.8nm;
Tightening Torque Shell Mounting Screws: 1.5-2.0nm;
Tightening Torque Knob Screws: 0.5-0.7nm;
Switching on or off Torque: 0.9-1.3nm;
The Wiring Torque on Base: 1.1-1.4nm;
Knob Positions: off at 9 Hr, on at 12 Hr;
Mechanical Life: 10000;
Number of DC Poles: 4 or 2;
Operation Temperature: -40 to +85;
Storage Temperature: -40 to +85;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p,2p,3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Current in (a): 6,10,15,20,25,30,35,40,50,63;
Poles: 1,2,3;
Rated Frequency (Hz): 50/60;
Rated Voltage Ue (V): 230/400;
Connection: From Top and Bottom;
Mechanical Life: 8500;
Electrical Life: 1500;
Installations: Plug-in;
The Material of Enclosure: Resin;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual / Automatic;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail Mount / Panel Mount;
Structure: Integrated Molded Case;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: AC220V/380V;
Rated Current: 16A~125A Optional;
Protection Function: Overload, Short-Circuit, Phase Loss, Under-Voltage;
Integrated Function: Integrated Start-Stop Control & Multi-Protection";
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual / Automatic;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail Mount / Panel Mount;
Structure: Integrated Molded Case;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: AC220V/380V;
Rated Current: 16A~125A Optional;
Protection Function: Overload, Short-Circuit, Phase Loss, Under-Voltage;
Integrated Function: Integrated Start-Stop Control & Multi-Protection";
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual / Automatic;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail Mount / Panel Mount;
Structure: Integrated Molded Case;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: AC220V/380V;
Rated Current: 16A~125A Optional;
Protection Function: Overload, Short-Circuit, Phase Loss, Under-Voltage;
Integrated Function: Integrated Start-Stop Control & Multi-Protection";
|