| Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vacuum Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Standard: IEC 60056;
Rated Voltage: 24kv;
Rated Current: 630A/1250A;
Mechanical Life: 10000 Times;
Protection: CT,Zero CT;
Operating Mechanism: Spring, Permanent Magnet;
Disconnector: One Side or Both Sides;
Service Environment: -40~++70 Celsius;
Pole: Epoxy Resin or Silicone Rubber;
Ftu: Bell Type or Box Type;
Delivery Time: Within 30 Days;
Breaking Time: 18-45ms;
Making Time: 25-60ms;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vacuum Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Standard: IEC 60056;
Rated Voltage: 24kv;
Rated Current: 630A/1250A;
Mechanical Life: 10000 Times;
Protection: CT,Zero CT;
Operating Mechanism: Spring, or Permanent Magnet;
Disconnector: One Side or Both Sides;
Rated Frequency: 50/60Hz;
Service Environment: -40~++70 Celsius;
Pole: Epoxy Resin or Silicone Rubber;
Ftu: Bell Type or Box Type;
Delivery Time: Within 30 Days;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: DC Miniature Circuit Breaker;
Rated Current: 63A,80A,100A,125A;
Rated Voltage: 250VDC/500VDC/750VDC/1000VDC;
Pole: 1p/2p/3p/4p;
Standard: IEC60898-1;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: DC Miniature Circuit Breaker;
Rated Current: 63A,80A,100A,125A;
Rated Voltage: 250VDC/500VDC/750VDC/1000VDC;
Pole: 1p/2p/3p/4p;
Standard: IEC60898-1;
|