| Specification |
After-sales Service: Online Video Service;
Warranty: 1 Year;
Appliance: Medical Research;
Detector: Uvd;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Flow Rate Range: 0-25 Ml/Min;
Pressure Range: 0-5 MPa (50 Bar, 725 Psi);
Viscosity: up to 5cp;
Wavelength Range: 190-850 Nm;
Wavelength Accuracy: ± 1 Nm;
Wavelength Repeatability: ± 0.2nm;
Optical Path Length: 2 mm;
Conductivity Range: 0-999.9 Ms/Cm;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Life Time Support Service;
Warranty: 1 Year for Transformer Oil Chromatograph Analysis;
Appliance: Transformer Oil Chromatograph Analysis;
Gaspath System: Double;
Detector: FID;
Chromatography Type: Gas Chromatography;
Test Item: Transformer Oil Chromatograph Analysis;
Key Word: Transformer Oil Gas Chromatography;
Test Standard: IEC 60599/ASTM D3612;
Power Supply: AC 220V±10%, 50Hz/60Hz;
Power: <500W;
Small Automatic Oscillator: 1 Set;
|
After-sales Service: Lifetime Technical Support,Online Service;
Warranty: 1 Year for Transformer Oil Dga;
Appliance: Transformer Oil Dissolved Gas Analysis;
Gaspath System: Double;
Detector: Two Fid and One Tcd;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Application: Dissolved Gas Analysis of Transformer Oil;
Gas Types That Can Be Analyzed: H2, O2, N2, Co, CO2, CH4, C2h4, C2h6 and C2h2;
Power Supply: Battery Charge;
Composition: Portable Chromatograph and Portable Oscillator.;
Control: Embedded Computer;
Tcd: Sensitivity:≥10000mv.Ml/Mg (Benzene;
Fid: Detection Limit:≤3*10-12g/S;
Ignition Mode: Program Automatic Ignition;
|