| Specification |
After-sales Service: Remote Service;
Warranty: Three Years;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 2~5mm;
Power Supply: 220V, 50Hz;
Ambient Temperature: 5℃ ~ 45 ℃ Ambient;
Humidity: 5% ~ 95%;
Power: 500W;
Detector Type: Fpd;
Measuring Range: 100ppb ~ 0.1%;
Detection Error: Constant ±5%; Trace ±10%;
Output Signal: 4 ~ 20mA;
Communication Mode: RS232 or RS485(Communication Protocol: Modbus RTU;
Net Weight: 12kg;
Dimensions: 390×230×310mm;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: Medical Research;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Double;
Detector: MSD;
Energy Resolution: ≤7.5%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Maximum Pressure: 63MPa;
Pressure Accuracy: ≤±3.0%;
Pressure Pulsation: ≤0.1MPa;
Wavelength Range: 190-800nm;
Wavelength Repeatability: ≤0.1nm;
Wavelength Accuracy: ≤±1.0nm;
Band Width: 6nm;
Response Time: 0.0s-5s;
Path Length: 10 mm(Analytical Cell);
Power Supply: AC110/220V±10%,  50/60Hz;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Gel Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Model: Bk-UV1800;
Optical System: Single Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 2nm;
Wavelength Accuracy: ± 0.5nm;
Photometric Accuracy: ± 0.002A (0~0.5ABS);
Stray Light: ≤ 0.05% T @ 360nm;
Stability: ± 0.001A / H @ 500nm;
Power Supply: AC110V/220±10% ,60/50Hz;
Packing Size(mm): 620*500*370;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: UV/Vis Spectrophotometer;
Gaspath System: Double;
Spectrometer Detector: Si(Li);
Optical System: Double Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Range: 1.8nm;
Wavelength Accuracy: ±0.3nm;
Wavelength Repeatability: ≤0.2nm;
Photometric Accuracy: ±0.002A(0~0.5ABS), ±0.004A(0.5~1.0ABS), ±0.3%T(0~1;
Stray Light: ≤0.04t@360nm; 220nm;
Stability: ±0.0003A/H@500nm;
Baseline Flatness: ±0.0005A;
Noise: ±0.0002ABS;
Photometric Mode: T, a, C, E;
Photometric Range: 0~200%T, -0.301~3.0A;
Light Source: Tungsten Lamp;
Input: Membrane Keypad;
Gross Weight: 25kg;
|
After-sales Service: on Line Service;
Warranty: One Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: X-Ray Spectrometer;
Gaspath System: Three;
Detector: MSD;
Energy Resolution: ≤7.5%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Power: 220 V, 50 Hz;
Temperature: 15-35c;
Humidity: 25%-80% Rh;
Column Oven Temperature: Room Temperature + 10c-400c;
Temperature Stability: <=-+0.03c;
Maximum Heating Rate: 40c/Min;
Maximum Run Time: 999.99 Min;
Pressure Range: 0-999 Kpa;
Flow Range: 0-200 Ml/Min;
Mass Range: 1.5-1024 Amu;
Mass Stability: Better Than 0.1 Amu/48 H;
Resolution: Unit Mass;
Maximum Scan Rate: 10,000 Amu/S;
Dynamic Range: 105;
Maximum Filament Current: 3 a;
|