| Specification |
Application: Electronic, High Voltage Power Transmission and Transformation;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Customized Structure of Multi-Layer Winding + Capa;
Insulating Medium: Insulating Oil;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage (Kv: 60, 66, 110, 120, 132, 138;
Rated Frequency (Hz: 50~60;
Creepage Distance (mm: 1820, 3155, 3630;
Rated Primary Current (a: 50~3200;
Accuracy Level: 0.2, 0.2s, 0.5, 0.5s, 5p, 10p;
|
Application: Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: Cosφ=0.8(Lag);
Air Relative Site: Indoor;
Altitude: Should Not Exceed 4000m;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Altitude: Should Not Exceed 4000m;
Air Relative Site: Outdoors;
Insulation Level: 40.5/95/200kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: Cosφ=0.8(Lag);
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 40.5/95/200kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Air Relative Site: Outdoors;
Altitude: Should Not Exceed 4000m;
Ambient Temperature: -40℃~+40℃;
|