| Specification |
Type: Infrared Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Customized;
Product Name: Carbon Dioxide Sensor;
Application: Home,Office,Industry,Air Quality Monitor;
Measure Range: 400-5000ppm (Extendable to 10000 Ppm);
Resolution: 1ppm;
Warm-up Time: 30s;
Operating Voltage: DC4.5~5.5V;
Batch Consistency: ≥90%;
Output M Ethod: Uart, Dac;
Working Temperature: 0~50ºC;
Working Humidity: 15~95%Rh;
Lifespan: 10 Years in Air;
|
Type: Infrared Gas Sensor;
Output Signal Type: Digital Type;
Material: Plastic;
Sensitivity: High;
Customized: Customized;
Measurement Ranges: 0-5%,0-20%,0-60%,0-100%;
Time to 1st Reading: <0.5 Seconds;
Response Time: Flow Dependent;
Readings Per Second: 20/50;
Sample Method: Solid-State LED Ndir Diffusion;
Supply Voltage: 3.25V-5.5V;
Power Consumption (Typ.): [email protected]/[email protected];
Operating Conditions -Temperature: 0℃ to 50℃;
Operating Conditions - Humidity: 0-95% Rh,Non-Condensing;
Storage Conditions - Temperature: -40°C to +70℃;
Ambient Operating Pressure: 500mbar to 2bar;
Sensor Lifetime: >15 Years;
|
Type: Infrared Gas Sensor;
Output Signal Type: Digital Type;
Material: Plastic;
Sensitivity: High;
Customized: Customized;
Gas: CO2;
Measurement Ranges: 0-5%,0-20%,0-60%,0-100%;
Response Time: <30 Seconds(Diffusion Limited);
Readings Per Second: 2;
Supply Voltage: 3.25V-5.5V;
Power Consumption (Typ.): <[email protected];
Operating Conditions -Temperature|0°C to: -25°C to 55°C(Extended);
Operating Conditions - Humidity: 0-95%Rh,Non-Condensing;
Storage Conditions -Temperature: -40°C to +70℃;
Ambient Operating Pressure: 500mbar to 2bar;
Sensor Lifetime: >15 Years;
Environmental Compliance: RoHS and Reach;
|
Type: Pid Sensor;
Output Signal Type: Analog Type;
Material: Stainless Steel;
Sensitivity: High;
Customized: Customized;
Working Voltage: 3.2-5.5V;
Zero Point Voltage: Uo> 20mv;
Response Time: ≤5s;
Operating Temperature: -40-+60℃;
Humidity: 0-99% Non-Condensing;
|
Type: Infrared Gas Sensor;
Output Signal Type: Digital and Analog Signals;
Sensitivity: High;
Customized: Customized;
Operating Voltage Range: 3.0 - 5.0V D.C.;
Operating Current: 75 - 85mA / 15mA / 140mA;
Operating Temperature Range: -20°C to +50°C (-4°F to 122°F);
Warm up Time: 60s;
Humidity Range: 0 to 95% Rh Non-Condensing;
Standard Baud Rates: 38,400, 19,200, 9600, 4800;
Mtbf: > 5 Years;
Weight: 15g;
Measuring Range: 0-5%, 0-100% Volume or Both / 0 - 1%, 0-2%, 0-5% V;
Response Time T90: <30s;
|