| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electromagnetic;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Working Voltage: 220/230/240 V;
Mechanical Life: 10,000 Times;
Electric Life: 4000 Times;
Protection Level: IP20;
Rate Current: 25A;
Residual Current: 30mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN RAIL;
Structure: MCB;
Poles Number: 1P+N, 3P, 3P+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC60898-1;
Protection Function: Short Circuit Protection, Overload Protection;
Rated insulation voltage: 500V;
Rated operating frequency: 50/60Hz;
Rated ultimate breaking capacity: 6000A;
Rated service breaking capacity: 6000A;
Rated Leakage Current: 10mA, 30mA, 100mA, 300mA, 500mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 2p and 4p;
Type: Circuit Breaker;
Function: RCCB;
Standards: IEC61008-1,En61008-2-1;
Poles: 1p+N,3p+N;
Rated Voltage: AC 240/415;
Rated Operating Break Capability: 10 INA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 6kv;
in: 10/16/20/25/32/40/50/63A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 6kv;
in: 10/16/20/25/32/40/50/63A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
|