| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Trip Curve: DC-Specific;
Rated Impulse Withstand (Uimp): 8kv;
Mounting: 35mm DIN Rail;
Operating Temperature: -25°C to +55°C;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: ACB;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Current: 200,400,630,800,1000,1250,1600A;
Control Voltage: AC220V;AC380V;
Controller Type: M(Default),F,3m,3h;
Number of Poles: 3p,4p;
Frame Grade Current: 1600A;
Design Code: Plastic Frame Integrated Circuit Breaker;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Main Circuit Rating Current: 1600/2000A;
Phase: 1/2/3;
Main Circuit Rating Voltage: 40.5KV;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Phase: 3;
Number of Pole: Fixed;
Main Circuit Rating Voltage: 12KV;
Main Circuit Rating Current: 3150/4000A;
Name: Embedded poles;
Shelf life: 20years;
Afterserivce: Yes;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Main Circuit Rating Current: 1600/2000A;
Phase: 1/2/3;
Main Circuit Rating Voltage: 40.5KV;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|