| Specification |
Task: Following;
Structure: Combination;
Mathematical Model: Non-Linear;
Signal: Continuous;
Function: Automatic Control, Protection;
Condition: New;
Customized: Non-Customized;
Material: Stainless Steel;
Series: Acs580-01 Series;
Warranty: 12 Months;
Supply Ability: 1000 Piece/Pieces Per Month;
Conditions: 100% Original;
Code: 85371011;
Materials: Stainless Steel;
Inventory: 200PCS;
Supply Voltage: 400V;
Scope of Application: Common;
Rated Power Kw(Lo): 0.75 Kw;
|
Task: Power Quality Monitoring & Analysis;
Structure: Open-Loop;
Mathematical Model: Non-Linear;
Signal: Continuous;
Function: Monitoring, Measurement;
Condition: New;
Customized: Non-Customized;
Allow Customized Logo: Yes (MOQ > 1000);
Power Supply: 95-277VAC/DC (Optional 20-60VDC);
Input Voltage: 400VLN/690VLL +20%;
Rated Current: 5A/1A, optional max. 500mV Input for use with SCCP;
Measuring Energy: 0~999999999.99kWh;
Accuracy (5A/1A option): IEC 62053-22 Class 0.2S for 5A/1A Option;
Accuracy (SCCPA): IEC 62053-21 Class 1 for SCCPA Option;
Frequency: 40Hz-72Hz;
Communication: RS-485, Ethernet;
|
Task: Power Quality Monitoring & Analysis;
Structure: Open-Loop;
Mathematical Model: Non-Linear;
Signal: Continuous;
Function: Monitoring, Measurement;
Condition: New;
Customized: Non-Customized;
Allow Customized Logo: Yes (MOQ > 1000);
Power Supply: 95-277VAC/DC (Optional 20-60VDC);
Input Voltage: 400VLN/690VLL +20%;
Rated Current: 5A/1A, optional max. 500mV Input for use with SCCP;
Measuring Energy: 0~999999999.99kWh;
Accuracy (5A/1A option): IEC 62053-22 Class 0.2S for 5A/1A Option;
Accuracy (SCCPA): IEC 62053-21 Class 1 for SCCPA Option;
Frequency: 40Hz-72Hz;
Communication: RS-485, Ethernet;
|
Task: Adjust;
Structure: Combination;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: Plastic;
Model: Gln Ultra-Thin Signal Isolator;
Input Signal: 4-20mA,0-5V,0-10V,1-5V,0-20mA;
Output Signal: 4-20mA,0-5V,0-10V,1-5V,0-20mA;
Channel: 1 in 1 out/1 in 2 out;
Power Supply: DC24V;
Accuracy: 0.1%Fs;
|
Task: Adjust;
Structure: Closed-Loop;
Mathematical Model: Non-Linear;
Signal: Continuous;
Function: Monitoring, Measurement;
Condition: New;
Customized: Non-Customized;
Allow Customized Logo: Yes (MOQ > 1000);
Power Supply: 95-277VAC/DC (Optional 20-60VDC);
Input Voltage: 400VLN/690VLL +20%;
Rated Current: 5A/1A, optional max. 500mV Input for use with SCCP;
Measuring Energy: 0~999999999.99kWh;
Accuracy (5A/1A option): IEC 62053-22 Class 0.2S for 5A/1A Option;
Accuracy (SCCPA): IEC 62053-21 Class 1 for SCCPA Option;
Frequency: 40Hz-72Hz;
Communication: RS-485, Ethernet;
|