| Specification |
Type: Vickers Hardness Tester;
Measuring Range: Hv, HK;
Application: Metal, Plastic, Ceramics and Glass, Stone;
Standard: ISO, ASTM, GB/T, BSEN;
Warranty: 1 Year;
Mobility: Desktop;
Calibrating Method: Length Scales and Standard Hardness Blocks;
Rated Voltage: 220V (110V for Optional);
Support Language: English or Chinese;
Customized: Customized;
Test Force (Load): 10g - 1000g;
Maximum Height: 90mm;
Throat Depth: 95mm;
Hardness Value Rang: 5hv-3000hv;
Hardness Value of Reading: Digital LCD Screen;
Magnification: 100X, 400X;
Loading Method: Automatically (Load, Dwell and Unload);
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Total Hardness;
Measuring Range: 0.53 - 534.0 ppm CaCO3;
Application: Demineralized Water Reverse Osmosis Boiler Water;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 220V;
Support Language: English;
Customized: Non-Customized;
Output: 4 - 20mA;
Measuring Principle: Titration Colorimetry;
Relay Output: 2 Passive Relay Output Nc / No, 250VAC 4A;
Optional Units: Mmol / L, Ppm CaCO3, ° Dh, ° F;
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Total Hardness;
Measuring Range: 0.20 - 500ppm CaCO3 (see reagent types);
Application: Demineralized Water Reverse Osmosis Boiler Water;
Standard: ISO;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Standard Hardness Test Blocks;
Rated Voltage: 24VDC, 25W;
Support Language: English;
Customized: Non-Customized;
Measuring Principle: Titration Colorimetry;
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Iron ions (divalent iron + trivalent iron);
Measuring Range: low range:0.01-0.5mg/L High range:0.2-6.0mg/L;
Application: boiler feedwater Drinking Water Iron removal Proce;
Standard: ISO;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Colourimetric method;
Rated Voltage: 85 - 265 VAC, 47-63Hz;
Support Language: English;
Customized: Non-Customized;
Measuring Principle: Titration Colorimetry;
|
After-sales Service: 1 year for the controller, consumables and accesso;
Type: Iron ions (divalent iron + trivalent iron);
Measuring Range: low range:0.01-0.5mg/L High range:0.2-6.0mg/L;
Application: boiler feedwater Drinking Water Iron removal Proce;
Standard: ISO;
Warranty: 1 Year;
Mobility: No;
Calibrating Method: Colourimetric method;
Rated Voltage: 85 - 265 VAC, 47-63Hz;
Support Language: English;
Customized: Non-Customized;
Measuring Principle: Titration Colorimetry;
|