| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 (Customized);
Accuracy Class: 0.1%, 0.2%, 0.5%;
Primary Current: 0 - 200A AC;
Secondary Current: 0 - 200mA AC or 0 - 200mv AC(Customized);
Max. Cont. Input Current: 240A;
Frequency Range: 40Hz-2000Hz;
Dielectric Strength: 3kv 50Hz/60Hz&Nbsp; at 1 Minute;
Output: 2.5 Meter Cable with D01 Connector;
Standard: En 61010-1, En 61010-2-032, IEC60044-1;
Color: Gray;
|
Application: Voltage Measurement, Metering, Relay Protection;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multi-Layer Winding;
Insulating Medium: Epoxy Resin;
Installation: Base Bolt Mounting;
Magnetic Circuit Structure: Closed Iron Core;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage Ratio: 10/0.1 Kv;
Accuracy Class: 0.2, 0.5, 3.0;
Rated Output: 20, 50, 100 Va;
Limit Output: 400 Va;
Insulation Level: 12/42/75 Kv;
Dimensions: 245mm × 210mm × 245mm;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Single-Turn Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
The Losd Power Factor: 0.8(Lag);
Product Standard: GB20840.2-2014;
Safety Factor: Fs≤10;
Pollution Class: Class LV;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Single-Turn Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
The Losd Power Factor: 0.8(Lag);
Product Standard: GB20840.2-2014;
Safety Factor: Fs≤10;
Pollution Class: Class LV;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 35kv;
Installation Method: Withdrawable;
Rated Frequency: 50/60Hz;
Material: Resin;
Coil Structure: Toroidal;
Model No.: Jdzxw-35;
Brand Name: Shengsu;
Color: Red;
Customize: Yes;
Size: Medium;
Ambient Temperature: -25-40;
Anti-Pollution Grade: Class IV;
Altitude: ≤2000m;
Power Factor: Cos=0.8(Lagging);
Standard: GB/T20840.1 GB/T20840.3;
|