| Specification |
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006;
Accuracy Class: 0.5%, 1%;
Range of Primary Rated Current: 300-3000A;
Range of Rated Load: ≤25va;
Rated Frequency: 50/ 60Hz;
Rated Secondary Current: 5A or 1A;
Safety Factor Rating: (Fs) < 5;
Aperture (mm): Φ185;
Weight (Kg): 4.5;
Key Word: 300/5A Split CT;
|
Application: Electronic, Instrument, Electricity Meter;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement, Electricity Meter;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|