| Specification |
Phase: Single Phase;
Type: On-line;
Protection: Overvoltage;
Application: Communication;
Classification: Lighting/Power;
Standby Time: Standard Machine;
Standby UPS: Sine Wave Output UPS;
Output Capacity: Medium Type;
Equipment Mode: Decentralized;
Brand: Gk;
Input Voltage: 3*400VAC (3pH+N);
Capacity: 10-200kVA;
Display: LED Display;
Rated Power: 10kVA,20kVA,30kVA,40kVA,60kVA,80kVA,100kVA,120K;
Relative Humidity: 0-95% (Non Condensing);
Material: Nonconductor;
|
Phase: Three Phase;
Type: Supercapacitor 3.0V 3400f;
Protection: IP65;
Application: Start The Power Supply;
Classification: Lighting/Power;
Standby Time: Standard Machine;
Standby UPS: Square Wave Output UPS;
Output Capacity: Medium Type;
Equipment Mode: Centralized Model;
Brand: Plannano;
Nominal Capacity C1: 566f;
Nominal Capacity Tolerances: 0%~+10%;
Equivalent Series Internal Resistance Es: ≤1.44MΩ;
Life Span: 4 Years;
Cycle Life: 1,000,000 Cycles;
|
Phase: Single Phase;
Type: On-line;
Protection: Overcurrent Protection;
Application: Data Center/Server/Medical Equipment/Communicatio;
Classification: Lighting/Power;
Standby Time: Standard Machine;
Standby UPS: Square Wave Output UPS;
Output Capacity: Medium Type;
Equipment Mode: Decentralized;
Brand: Dtvs;
Efficiency: 0.98;
Output Current: 32A;
Output Voltage: 220V;
Output Frequency: 50/60Hz;
|
Phase: Three Phase;
Type: On-line;
Protection: Overload, Short Circuit, Overcurrent, Overvoltage;
Application: Industry;
Classification: Lighting/Power;
Standby Time: Standard Machine;
Standby UPS: Sine Wave Output UPS;
Output Capacity: Large Type;
Equipment Mode: Centralized Model;
Brand: Zlpower;
UPS Display: Multiple Language English Italian French Russia;
UPS Name: Modular UPS 60kVA 90kVA120kVA PF 0.9 3 Phas;
Design: up to 20 Power Modules in Parallel Online Hot-Swap;
Input Output Voltage: 3 Phase 380V 415V;
DC Voltage: 480V;
Battery Compatible: Lead Acid, Battery, Lithium Battery;
IGBT: Integrated IGBT Design;
Advantage: Less Failure Points with Higher Performance and Re;
Interface: RS232, RS485, Programmable Dry Contact;
Optional: Snmp Card, Parallel Kit, SPD, Lbs, Dust Filter;
LCD: 5.7" Touch Screen LCD + LED + Keyboard;
Temperature: Operation: 0- 40 Storge: -40 -70;
Applicant: Safety: IEC/En 62040-1 EMC: IEC/En 62040-2 Perfor;
Battery Cold Start: Default;
Transfer Time: 0ms;
|
Phase: Three Phase;
Type: On-line;
Protection: Overload, Short Circuit, Overcurrent;
Application: Communication;
Classification: Lighting/Power;
Standby Time: Standard Machine;
Standby UPS: Sine Wave Output UPS;
Output Capacity: Small Type;
Equipment Mode: Decentralized;
Product Name: 100kVA 120kVA 160kVA Three Phases Online UPS for F;
LED/LCD Display: AC/DC Voltage, Battery Status Load etc;
Multiple Protections: Overload, Shortciscuit, Over Temp etc;
Warranty: 24 Months Warranty;
Input Voltagerange: 380V 4150V 400V;
Outlet: Terminal Block;
Battery Voltage: 240V 480V 384V;
Snmp Card: Remote Control Available;
Transfer Time: Zero;
Power Factory: 1.0 or 0.9;
Battery: Lithium Battery or Lead Acid Battery;
|